© Copyright 2011 Zoeller Co. All rights reserved.

WD & WH MODEL INSTALLATION

WIRING DIAGRAM FOR MODELS

WD - 230V, 1 Ph, 60 Hz.

WH - 200/208V, 1 Ph, 60 Hz.

Models WD & WH are fully automatic. A float switch is included and 

factory wired in the pump circuit to provide automatic operation 

once the float switch is secured properly to the outlet pipe. Use the 

diagram above to secure the float switch properly and obtain the 

proper tether to customize the on-off cycle to each application.

Determining Pumping Range

in Inches (1 inch - 2.5 cm)

Tether Length 

5  10  15 20 22

Pumping Range 

9 13.5 18 22 24

max.

Use only as a guide. Due to weight of 

cable, pumping range above horizontal 

is not equal to pumping range below 

horizontal. Ranges are based on testing in 

nonturbulent conditions.

 Range may vary 

due to water temperature and cord shape. 

As tether length increases, so does the 

variance of the pumping range.

min.

START

RUN

BLUE

MOTOR

(WHITE)

RED

(BROWN)

O.L.

YELLOW

(BLACK)

SWITCH

FLOAT 

BLACK

BLACK

WHITE

CAPACITOR

BLUE

(1)

(2)

RED

RUN

WHITE

GREEN

L1

L2

(3)

011835

Note: Failure to keep within proper tether limits 

may prevent reliable switch operation.

Note: 

Cable must be mounted in horizontal 

position.

22" MAX.

5" MIN.

20 AMP SWITCH (WD & WH MODELS)

SK305

THREE PHASE WIRING INSTRUCTIONS

 FOR YOUR PROTECTION, ALWAYS 

DISCONNECT PUMP FROM ITS POWER SOURCE 

BEFORE HANDLING.

To automatically operate a nonautomatic three phase pump, a 

control panel is required.  Follow the instructions provided with the 

panel to wire the system.  For automatic three phase pumps see 

automatic 3 phase wiring diagram located to the far right.
Before installing a pump, check the pump rotation to ensure that 

wiring has been connected properly to power source, and that 

the green lead of power cord (See wiring diagram), is connected 

to a valid ground. Momentarily energize the pump, observing the 

directions of kick back due to starting torque. Rotation is correct if 

kick back is in the opposite direction of rotation arrow on the pump 

casing. If rotation is not correct, switching of any two power leads 

other than ground, should provide the proper rotation.

All three phase pumps require motor starting devices with motor 

overload protection. See FM0486 for duplex installations.  Pumps

must

 be installed in accordance with the National Electrical Code 

and all applicable local codes and ordinances. Pumps are not to 

be installed in locations classified as hazardous in accordance 

with National Electrical Code, ANSI/NFPA 70.

NONAUTOMATIC

3 PHASE

AUTOMATIC

3 PHASE

MOTOR

(3)

BLUE

RED

BLACK

GREEN/YELLOW

L1

L2

(1)

(2)

YELLOW

L3

GREY

BROWN

013071

SINGLE PHASE WIRING INSTRUCTIONS

 FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING.  Single phase pumps 

are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES 

REMOVE THE GROUND PIN.

  The 3-prong plug 

must  be inserted into a mating 3-prong grounded receptacle. If the installation does not have such 

a receptacle, it must be changed to the proper type, wired and grounded in accordance with the National Electrical Code and all applicable local codes 

and ordinances.

 “Risk of electrical shock”  Do not remove power supply cord and strain relief or connect conduit directly to the pump.

 Installation and checking of electrical circuits and hardware should be performed by a qualified licensed electrician.

 Units supplied without a plug (single and three phase) and single phase nonautomatic units with a 20 amp plug must have a motor control 

and liquid level control provided at time of installation. The control device should have suitable voltage, ampere, frequency, grounding and horsepower 

rating for the pump to which it is connected.

IMPORTANT NOTICE: 

Some insurance policies, both commercial and residential, extend coverage for damages incurred by product failure. You will need to 

have possession of the product to support your claim in most cases. Zoeller Pump Co. will exchange the unit or refund the original purchase price once the claim 

is settled with the insurer in the case where you need to retain possession of the product to support a damage claim you submit to your insurance company.

006848

Summary of Contents for 49 Series

Page 1: ...ified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electric shock These pumps have not been investigated for use in swimming pool and mar...

Page 2: ...rvice Stations Go to www zoellerpumps com servicestations to find the Authorized Service Station in your area SERVICE CHECKLIST EASY DO S DON T S FOR INSTALLING A SUMP PUMP 1 DO read thoroughly all in...

Page 3: ...nder Caution on front page Water stream will be visible from this hole during pump run periods 5 Securely tape or clamp power cord to discharge pipe clear of the float mechanism s 6 Use full size disc...

Page 4: ...rect switching of any two power leads other than ground should provide the proper rotation All three phase pumps require motor starting devices with motor overloadprotection SeeFM0486forduplexinstalla...

Page 5: ...iable o las bom bas no autom ticas que usan interruptores de flotador de nivel variable auxiliares es responsabi lidad del instalador y deber verificarse que el interruptor de flotador atado no se eng...

Page 6: ...umidero 6 INSTALE una v lvula de retenci n y una uni n en la tuber a de descarga JAM S use una tuber a de descarga de menor tama o que la descarga de la bomba 7 JAM S use una bomba de sumidero como un...

Page 7: ...ATICAS UTILICE EL ESQUEMA PARA LA INSTALACION PARAACHIQUE M S ABAJO 12 Los sellos herm ticos contra gases son necesarios en todas las instalaciones de aguas cloacales a fin de contener los gases y olo...

Page 8: ...osee un tomacorriente de este tipo se debe cambiar por uno apropiado cableado y con puesta a tierra de acuerdo al C digo El ctrico Nacional y a todas las ordenanzas y c digos locales aplicables ADVERT...

Page 9: ...roits classifi s risque conform ment la norme ANSI NFPA 70 du Code national am ricain de l lectricit 7 Risque d lectrocution Ne pas enlever le cordon d alimentation ni le distributeur de tension m can...

Page 10: ...d autres droits qui varient d une province l autre GARANTIE LIMIT E Le fabricant garantit l acheteur et au propri taire ult rieur pendant la p riode de garantie tout produit neuf contre tout vice de...

Page 11: ...tiliser un tuyau de refoulement de pleines dimensions 7 Le puits doit tre conforme tous les r glements applicables 8 Avant la mise en service la pompe doit tre de niveau et le m canisme du flotteur ne...

Page 12: ...es limites appropri es Remarque Le c ble doit tre install horizontalement Longueur du bras d attache Plage de pompage 5 10 15 20 22 9 13 5 18 22 24 5 po min 22 po max SK305 Interrupteur 20 amps mod le...

Reviews: