- 2 -

 

LIMITED WARRANTY

 

 

 

 

 

Manufacturer warrants, to the purchaser and subsequent owner during the 

warranty period, every new product to be free from defects in material and 

workmanship under normal use and service, when properly used and 

maintained, for a period of one year from date of purchase by the end user, or 18 

months from date of original manufacture of the product, whichever comes first. 

Parts that fail within the warranty period, one year from date of purchase by the 

end user, or 18 months from the date of original manufacture of the product, 

whichever comes first, that inspections determine to be defective in material or 

workmanship, will be repaired, replaced or remanufactured at Manufacturer's 

option, provided however, that by so doing we will not be obligated to replace an 

entire assembly, the entire mechanism or the complete unit. No allowance will be 

made for shipping charges, damages, labor or other charges that may occur

due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any material or 

product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or uncontrolled 

act of nature; that has not been installed, operated or maintained in accordance 

with Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following: sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or any other abusive entity, etc. 

in all pumping applications. The warranty set out in the paragraph above is in 

lieu of all other warranties expressed or implied; and we do not authorize any 

representative or other person to assume for us any other liability in connection 

with our products. Contact authorized distributors to obtain any needed repair or

replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF 

EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY

OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY 

SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some jurisdictions do not allow limitations on the duration of an implied 

warranty, so the above limitation may not apply to you. Some jurisdictions do not 

allow the exclusion or limitation of incidental or consequential damages, so

the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights

which vary from  jurisdiction to jurisdiction.       

Pump should be checked frequently for debris and/or build up which may 

interfere with the float “on” or “off” position. Repair and service should be

performed by an authorized Zoeller Company Representative only. 
Do not operate a pump in an application where the Total Dynamic Head is 

less than the minimum Total Dynamic Head listed on the Pump Performance

Curves.
For health reasons, do not unplug, turn off, or disable pump and use pump tank

system as a way to fill up a sink or laundry tray, etc. 

Check  to  be  sure  your  power  source  is  capable  of  handling  the  voltage

requirements of the motor, as indicated on the pump name plate.
The installation of variable level float switches is the responsibility of the  

installing party, and care should be taken that the tethered float switch will 

not hang up on the pump apparatus or pit peculiarities and is secured so that  

the pump will shut off.  It is recommended to use rigid piping and fittings and 

the pit be 45 cm (18”) or larger in diameter.
Vent hole. It is necessary that all submersible sump, effluent and sewage 

pumps capable of handling various sizes of solid waste be of the bottom

intake  design  to  reduce  clogging  and  seal  failures.  If  a  check  valve  is 

incorporated in the installation,  a  5  mm  (3/16")  vent  hole  must  be  drilled

in  the  discharge  pipe  below  the  check valve and pit cover to purge the 

unit of trapped air.  Vent hole should be checked periodically for clogging.

The vent hole on a High Head application may cause too much turbulence. 

You may not want to drill one. If you choose not to drill a vent hole, be sure

the pump case and impeller is covered with liquid before connecting the pipe 

to  the  check  valve.  NOTE:  THE  HOLE  MUST  BE  BELOW  THE  BASIN

COVER AND CLEANED PERIODICALLY. Water stream will be visible when

pump is operating.    

SEE BELOW FOR LIST OF CAUTIONS

1.

2.

3.

4.

5.

6.

EASY DO’S & DON'T’S FOR INSTALLING UNIT

 

  

   

 

 

 

 

 

DO

 read all installation material included with the pump.

1.

 

DO

DO

 inspect unit for any visible damage caused by shipping. Contact dealer

if unit appears to be damaged.

2.

 

DO 

remove all debris from the basin. Be sure that the pump will have a hard, 

level surface beneath it. 

DO NOT

 install on sand, gravel or dirt. 

3.

 

DO 

be sure that the area is large enough to allow proper clearance for the

level control switch(es) to operate properly.

4.

DO always disconnect pump from power source before handling.

DO 

always connect to a separately protected and properly grounded circuit. 

DO NOT

 ever cut, splice or damage power cord (only splice in a watertight

junction box).

DO NOT

 carry or lift pump by its power cord.

DO NOT

 use an extension cord.

5.

 

DO 

install a check valve and a union in the discharge line.

 

6.

DO NOT 

use a discharge pipe smaller than the pump discharge size.

 

DO

 

NOT

 utilize this unit for pumping gasoline or other hazardous liquids.

7.

 

DO

 test pump immediately after installation to be sure that the system is 

working properly.

8.

 

 

DO 

review all applicable local and national codes and verify that the

installation conforms to each of them.

9.

   

DO

12.

 inspect and test system for proper operations at least every 3 months.

 

DO 

consider a D.C. Backup System is necessary for the prevention of 

11.

property damages from flooding due to A.C. power disruptions, mechanical 

or electrical problems or system overloading.

 

10.

DO 

consult manufacturer for clarifications or questions.

© Copyright 2018 Zoeller   Co. All rights reserved.

®

In those instances where damages are incurred as a result of an alleged pump failure, 

the Homeowner must retain possession of the pump for investigation purposes.

Summary of Contents for 2802

Page 1: ...rning use of the appliance by a person responsible for their safety 8 Risk of electrical shock Do not remove power supply cord and strain relief or connect conduit directly to the pump If the supply cable is damaged it must be replaced by an authorized Zoeller Representative 9 Pump may contain oil which becomes pressurized and hot when operating Allow 2 1 2 hours after disconnecting before attempt...

Page 2: ...ic Head listed on the Pump Performance Curves For health reasons do not unplug turn off or disable pump and use pump tank system as a way to fill up a sink or laundry tray etc Check to be sure your power source is capable of handling the voltage requirements of the motor as indicated on the pump name plate The installation of variable level float switches is the responsibility of the installing pa...

Page 3: ...wearing insulated protective sole shoes and not standing in water Under flooded conditions contact your local electric company or a qualified licensed electrician for disconnecting electrical service to the pump prior to removal before attempting service General Maintenance Repair and service should be performed by a Zoeller Pump Company Authorized Service Station only SAFETY PROCEDURES For your p...

Page 4: ...mp 9 Basin must be clean and free of debris after installation 10 Gate Valve or Ball Valve to be supplied by installer and installed according to any and all codes 11 es The best place for the off point is above the motor housing and positioned 180 from the inlet Never put off point below discharge on pump 12 Gas tight seals required to contain gases and odors 13 Vent gases and odors to the atmosp...

Page 5: ... 5 Copyright 2018 Zoeller Co All rights reserved Model 2802 Model 2812 SINGLE PHASE WIRING DIAGRAM Start Capacitor Run Capacitor Model No 2802 2812 400 µF 250 VAC 90 µF 250 VAC ...

Page 6: ...果水 5 保固請參閱第07頁 為防範觸電 本產品勿用於游泳池 11 為避免觸電 請勿移除電纜線 如果電纜線受損 請聯 8 若無監督本產品不適合給兒童 心智不健全或經驗不足 7 水泵不可使用於飲用水 冷卻油有可能會污染水質 10 絡經銷商或本公司核可的服務單位維修 泵使用電線直接連接 需在電控箱內斷電 任何情況下 都不允許移除接地插銷 確保人未站在水中 且穿上絕 緣鞋 泵配有接地插頭的設計 以幫助防止觸電 必須 按國內法規 正確安裝接地的插座或控制箱 等待2 5小時再進行維修 本水泵含冷卻油 在運作狀態下會受壓變熱 斷電後 9 請 勿 使 用 於 油 類 汽 油 石 油 產 品 或 含 任 何 化 學 成 分 的 液 體 CAUTION 安全守則 為避免嚴重或致命的人身傷害及重大財產損失 請閱讀並 遵守水泵的所有安全操作說明 本說明書在協助安裝和操作本機型時 必須符合水泵的安 全操作守則 這...

Page 7: ...造成的故障或損壞 抽取沙 碎石 水泥 泥巴 瀝青 碳氫化合物及其衍生 物 汽油 化學溶劑或其他有腐蝕性的液體 毛巾 女性 衛生用品等 2 不當操作 意外或疏忽所造成故障或損壞 3 加裝不屬於本產品的零 配件 4 未依照當地法規進行安裝所造成的危害 本公司無法控制的損壞不在保固範圍內 保固不適用於 保固零 配件的退回 在本保固之下任何修理或更換需送 回本公司或其他本公司所指定的維修服務點 運費需自付 上述為本產品唯一的保固說明 任何人的修改或另做承諾 皆為無效 在任何情況下本公司不負擔其他責任 包含資產或設備的 本公司的責任不超過產品的實售價格 損壞 利潤損失 等 5 3 一般沉水型污水泵都是從底部抽水 以防止水泵阻塞 和洩漏 空氣會因此容易積在水泵或管路內 造成氣 鎖 排氣孔是為了將這些空氣排出 因此 必須在 逆止閥與機坑蓋下的管路鑿一排氣孔 直徑約5 mm 能源自於水泵運作時的攪動 或於...

Page 8: ...關閉總電源斷路器 拔除水泵插頭 確保人未站在水中 且穿上絕緣保護底的鞋子 水溢流時 聯絡當地的電力公司 或有執照的合格電氣技師 在移除管之前進行斷電 本水泵含冷卻油 在運作狀態下會受壓變熱 斷電後等待2 5 小時再進行維修 警 告 警 告 警 告 警 告 警 告 版權所有 2018 Zoeller 公司 翻印必究 8 一般維修 安全程序 注意事項 產品維修及維護須由卓勒泵浦公司授權 之合格維修站來執行 為了您的安全考量 在執行作業前請先將泵浦及控 制面板上的電源插頭拔除 方 任何人進入桶裝地方 須穿著安全護具並繫上可延伸 至到地面的安全繩 以防人員窒息時可以被救出 污水會 排放出甲烷和硫化氫氣體 二者都是具有高毒性 進行清理和清潔 在系統被安裝好開始運轉前 須由合格工程技師執行檢驗 電路及其硬體設備安裝及檢查須由合格之電工人員來執 行 請勿用電源線來拉提泵浦 在沒有適當地執行排氣與測試前 ...

Page 9: ...靠 並使其避開浮子開 關機構 出水管管徑不可小於水泵出口口徑 水槽需符合適用規範及規格 啟動水泵前確認水泵水平 且浮子開關機構與水槽邊牆保 持淨空距離 並確認浮子開關機構不被入水水流干擾 完成安裝後必須清理水槽內所有雜物碎屑 閘閥或球閥由安裝者提供 並需依照所有相關規範安裝 如圖示安裝浮球開關 停止 點的最佳位置為馬達外殼 上方 與入口成180 的方位 切勿將 停止 點配置在水 泵出口以下 應使用氣密密封圈隔絕氣體與氣味 利用通氣管將氣體與氣味排出 1 2 3 4 6 7 8 9 10 11 12 13 5 SK1217 維修蓋 標準管路法蘭 PVC管或輕質不鏽鋼管 小礫石 鋼蓋板水池上標準浮子安裝桿 某些安裝場合可能需要利用獨立的浮子桿安裝各控 制開關 以免牽掛到水泵 管路 閥門等 卓勒提 供各種浮子桿 請參考FM0526型錄 也可利用標準 管材與配件製作 安裝示意圖 3 16 DIA ...

Page 10: ... EA0115 EA0116 2802 2812 400 µF 250 VAC 90 µF 250 VAC 運轉電容 啟動電容 型號 棕色 白色 黑色 黑色 灰色 紅色 棕色 白色 黑色 黑色 灰色 紅色 綠黃色 綠色 濕度感應器 下 濕度感應器 熱感應器 上 綠黃色 綠色 黑色 紅色 白色 黑色 紅色 白色 斷路器 離心器 離心器 運轉電容 啟動電容 運轉電容 啟動電容 黑色 紅色 綠色 白色 黑色 黑色 黑色 綠色 白色 白色 橘色 紅色 紅色 紅色 紅色 棕色 橘色 橘色 熱保護器 熱保護器 馬達 馬達 控制箱 啟動線繞組 啟動線繞組 主線繞組 主線繞組 主線繞組 Model 2802 Model 2812 ...

Page 11: ... 11 版權所有 2018 Zoeller 公司 翻印必究 警 告 12 10 金屬螺絲 x 1 2 L1 L2 單相斷路器接線圖 手動復歸型 藍色 白色 藍色 白色 綠色 綠黃色 棕 色 斷路器 單相水泵 電源線 電源 控制箱 藍 色 在控制背板鑽洞3 mm 以安裝斷路器支架 這是原始安裝說明的翻譯資料 白 色 黑 色 ...

Reviews: