10
INSTALLATION INSTRUCTIONS
16. Install a basin cover and gasket (not included) on the
top of the basin. This will contain gases and odors,
prevent debris from falling into the basin, and prevent
personal injury.
Basin
cover
and
gasket
16
17. Install a vent pipe (not included) according to local,
regional, or state codes to remove gases and odors.
Vent
pipe
17
TROUBLESHOOTING
Problem
Possible Cause
Corrective Action
Pump will not
start or run.
1. Water level too low.
1. Water must be at the appropriate level
to activate switch.
2. Blown fuse or tripped circuit breaker.
2. If blown, determine cause and then
either replace with properly sized fuse,
or reset breaker.
3. Low line voltage.
3. Contact an electrician.
4. Motor is defective.
4. Replace pump.
5. Switch is defective.
5. Replace switch.
6. Inlet screen clogged.
6. Remove debris.
7. Switch is obstructed.
7. Remove obstruction to ensure free
motion of switch.