GRINDER PUMP

MODEL #2701

Serial Number

Purchase Date

Zoeller

®

 is a registered trademark 

of Zoeller Co. All Rights Reserved.

Questions, problems, missing parts? Before returning to your retailer, call our customer 

service department at 1-800-584-8089, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.

ATTACH YOUR RECEIPT HERE

SW1220 C

ZoellerAtHome.com

Summary of Contents for 2701

Page 1: ...ler is a registered trademark of Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE SW1220 C ZoellerAtHome com ...

Page 2: ...inst the possibility of electrical shock DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN ELECTRICAL SHOCK ALERT To reduce the risk of electric shock install only a circuit protected by a ground fault circuit interruptor GFCI ELECTRICAL SHOCK ALERT Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity A separate branch circuit is recommended...

Page 3: ...embly not included Adjustable wrench hacksaw flathead screwdriver Phillips screwdriver tape measure utility knife pipe wrench Description Quantity Pump 1 Switch 1 PREPARATION Parts Required For Assembly not included Sewage pump basin minimum 18 in w x 30 in deep basin cover basin gasket 1 1 4 in check valve 1 1 4 in union gate valve or ball valve as required by codes 1 1 4 in Schedule 40 PVC pipe ...

Page 4: ...not recommended for pumping from a residence to a septic tank They are designed to pump long distances 750 feet or more and or high lifts minimum of 30 feet 2 These pumps are shipped with a float switch which attaches to the discharge pipe The pump will turn on automatically when the water level in the basin reaches the on level of the switch On 2 Off 3 3 The pump will turn off automatically when ...

Page 5: ...8 in 1 Use a basin not included that is at least 18 in wide by 30 in deep 1 2 Clean the basin of all debris 2 3 Set the pump on a solid level surface A brick or block not included may be installed under the pump to provide a solid base 3 ...

Page 6: ...The best place for the off point is above the motor housing and 180 from the inlet Never put the off point below the pump discharge 4 Install rigid 1 1 4 in discharge pipe not included according to local regional and state codes Incoming water Switch Discharge Pipe 5 Use a 2 step PVC glue system not included to join pipe and any fittings needed 5 ...

Page 7: ...inimum Discharge Pipe 8 Drill a 3 16 in hole in the discharge pipe above the pump discharge to prevent air lock Water stream will be visible from this hole when the pump is running The hole must be cleaned periodically 9 Install a 1 1 4 in union not included above the basin to allow the pump to be removed for cleaning and service Discharge pipe 3 16 in hole Union 8 9 ...

Page 8: ... union to prevent back flow 11 Install a 1 1 4 in gate valve or ball valve not included above the check valve as required by local regional or state codes 12 Connect remaining discharge pipe into main waste line Check Valve Gate Valve Main waste line 10 11 12 ...

Page 9: ... freely 14 Plug power supply cord into piggyback switch cord Connect piggyback switch cord to a receptacle protected by a ground fault circuit interruptor GFCI Cable or zip tie GFCI protected receptacle 13 14 15 Fill the basin with water to check operation The pump will start when the water level has reached the switch on level On 15 ...

Page 10: ...t pipe 17 TROUBLESHOOTING Problem Possible Cause Corrective Action Pump will not start or run 1 Water level too low 1 Water must be at the appropriate level to activate switch 2 Blown fuse or tripped circuit breaker 2 If blown determine cause and then either replace with properly sized fuse or reset breaker 3 Low line voltage 3 Contact an electrician 4 Motor is defective 4 Replace pump 5 Switch is...

Page 11: ...eller is clogged or damaged 2 Where applicable remove screen and volute clean impeller or replace impeller 3 Piping attachment to building structure too rigid or too loose 3 Install rubber coupling not included to isolate pump vibration from discharge piping Pump will not shut off 1 Switch is defective 1 Replace switch 2 Switch is obstructed 2 Remove obstruction to ensure free motion of switch 3 D...

Page 12: ...in connection with such service d to units which are not installed in accordance with normal applicable local codes ordinances and good trade practices and e if the unit is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville Indiana or such ...