6
© 2020. All rights reserved.
7
© 2020. All rights reserved.
Water
Level
Suction
Lift
Pipe
Support
Unions
Foot
Valve
3
3. All piping from the well to the pump should slope
slightly upward with no sagging. Support suction
pipe between water source and pump. Unions in
the suction line near the pump and well will aid in
servicing. Be sure to leave enough room so that
wrenches can be used easily.
Replace foot valve for best performance.
WELL TO PUMP CONNECTION (SUCTION PIPE) - DEEP WELL
1. Make the connection to your well. Wrap all
threaded fittings with pipe tape 5 times or apply
a pipe paste (pipe dope) to ensure an air tight
connection.
IL1395
Tape
1
IL1396
2
2. Finish the connection to your well with additional
pipe and fittings as needed.
PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE) - DEEP WELL
1. To begin the connection to the pressure tank,
install the 1 in x 3/4 in adapter (included) to pump
discharge. Install flow control body to adapter.
Using Teflon tape, position the discharge outlet of
the control body facing right as you look directly
into the face of the pump
IL2206
Control
Body
Flow Control
Screw
1 in. x 3/4 in. adapter
1
2. Assemble the pressure switch in the 1/4” tapping
adjacent and to the right of the discharge outlet
of the control valve. Refer to Pump Electrical
Connection section for pressure switch wiring.
IL1389
2
3. Tighten flow control body.
IL1390
3
IL1391
4
4. Install optional pressure gauge in 1/4” tapping
on side of pump body. Face of gauge should be
positioned so that dial can be read easily.