3.   All piping from the well to the pump should slope 

slightly upward with no sagging. Support suction 

pipe between water source and pump. Unions in 

the suction line near the pump and well will aid in 

servicing. Be sure to leave enough room so that 

wrenches can be used easily. 

 

Replace foot valve for best performance.  

WELL TO PUMP CONNECTION (SUCTION PIPE) - DEEP WELL

 1.   Make the connection to your well. Wrap all 

threaded fittings with pipe tape 5 times or apply 

a pipe paste (pipe dope) to ensure an air tight 

connection.

IL1395

Tape

1

IL1396

2

2.   Finish the connection to your well with additional 

pipe and fittings as needed. 

PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE) - DEEP WELL

1.  To begin the connection to the pressure tank, 

install the 1 in x 3/4 in adapter (included) to pump 

discharge. Install flow control body to adapter. 

Using Teflon tape, position the discharge outlet of 

the control body facing right as you look directly 

into the face of the pump

IL2206

Control 

Body

Flow Control 

Screw

1 in. x 3/4 in. adapter

1

  2.   Assemble the pressure switch in the 1/4” tapping 

adjacent and to the right of the discharge outlet 

of the control valve. Refer to Pump Electrical 

Connection section for pressure switch wiring.

IL1389

2

  3.   Tighten flow control body.

IL1390

3

IL1391

4

  4.   Install optional pressure gauge in 1/4” tapping 

on side of pump body. Face of gauge should be 

positioned so that dial can be read easily.

Summary of Contents for 1463-0006

Page 1: ...oblems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE Zoeller is a registered trade...

Page 2: ...nd can run on 115 V or 230 V It is factory pre set to run on 230 V ELECTRICAL SHOCK ALERT SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble operate or inst...

Page 3: ...GA 50 100 115 V 230 V 10 GA 14 GA 100 150 115 V 230 V 10 GA 12 GA 150 200 115 V 230 V 8 GA 12 GA 200 300 115 V 230 V 6 GA 10 GA Fuse Size 115 V 230 V Amps 30 15 Pipe And Fittings Use galvanized steel...

Page 4: ...ction IL1395 Tape 1 IL1396 2 2 Finish the connection to your well with additional pipe and fittings as needed PUMP TO PRESSURE TANK CONNECTION DISCHARGE PIPE DEEP WELL 1 To begin the connection to the...

Page 5: ...ressure tanks will have a 1 inch inlet elbow on the bottom Connect to this elbow with a 1 in MPT x 1 in slip glue adapter and short piece of pipe 2 Install a 1 in elbow IL1365 Glue Adapter Pipe IL1366...

Page 6: ...4 in opening on the side of the flow control and remove the switch cover C US LR90197 UL Std No 778 ENCLOSURE 3 starwatersystems com Pump JHU10 Rev B Motor 98U1071 HP 1 PH 1 Hz 60 Volts 115 230 S F 1...

Page 7: ...rce Use copper conductors only ELECTRICAL HAZARD Improper installation may result in fire explosion electrical short or injury Replace all covers before operating Ground motor in accordance with local...

Page 8: ...d register on the gauge mounted on the pump body If pressure does not build repeat priming operation All air must be vented from the drive and suction pipes as well as the body before the pump will pr...

Page 9: ...place all covers before operating Ground motor in accordance with local and national electrical codes Disconnect power source before touching internal parts Motors equipped with automatic protection m...

Page 10: ...nted for two years from the date of purchase Subject to the conditions hereinafter set forth the manufacturer will repair or replace to the original consumer any portion of the product which proves de...

Reviews: