background image

8

© 2020. All rights reserved.

9

© 2020. All rights reserved.

INSTALLATION INSTRUCTIONS

10. Install a 2 in. check valve (not included) above the 

union to prevent back-flow.

11. Install a 2 in. gate valve (not included) above the check 

valve as required by local, regional or state codes. 

12. Connect remaining discharge pipe into main waste 

line to sewer or septic tank.

Check

Valve

Gate

Valve

Main 

waste line

10

11

12

INSTALLATION INSTRUCTIONS

13. Attach power supply cord to discharge pipe using 

cable or zip ties (not included) to allow the float switch 

to move freely.

14. Connect pump power supply cord to a receptacle 

protected by a ground fault circuit interruptor (GFCI).

Cable or

Zip Ties

GFCI 

protected 

receptacle

13

14

15. Fill the basin with water to check operation. The pump 

will start when the water level has reached the switch 

“on” level. Refer to page 4 for “on” level.

On

15

Summary of Contents for 1263

Page 1: ...se Date Zoeller is a registered trademark of Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE SW1316 B ZoellerAtHome com ...

Page 2: ... or circuit breakers of proper capacity A separate branch circuit is recommended sized according the National Electrical Code for the current shown on the pump name plate CHEMICAL ALERT Prop65 Warning for California residents WARNING Cancer and Reproductive Harm www P65Warnings ca gov CAUTION CAUTION PRODUCT DAMAGE MAY RESULT Make certain that the power source conforms to the requirements of your ...

Page 3: ...k Main waste line to sewer or septic tank Switch Pump 1 2 These pumps are equipped with a float switch The pump will turn on automatically when the water level in the basin reaches the on level On 2 Off 3 Item On Level Off Level 1263 10 25 in 5 in 3 The pump will turn off automatically when the water level in the basin reaches the off level GENERAL PUMP INFORMATION INSTALLATION INSTRUCTIONS 30 in ...

Page 4: ...codes Incoming water Switch Switch 1 in Minimum Discharge Pipe INSTALLATION INSTRUCTIONS 7 Use a 2 step PVC glue system not included to join pipe and any fittings needed 8 Drill a 3 16 in hole in the discharge pipe above the pump discharge to prevent air lock Pumps have a vent located in the pump but an additional vent hole is recommeded Water stream will be visible from this hole when the pump is...

Page 5: ...o sewer or septic tank Check Valve Gate Valve Main waste line 10 11 12 INSTALLATION INSTRUCTIONS 13 Attach power supply cord to discharge pipe using cable or zip ties not included to allow the float switch to move freely 14 Connect pump power supply cord to a receptacle protected by a ground fault circuit interruptor GFCI Cable or Zip Ties GFCI protected receptacle 13 14 15 Fill the basin with wat...

Page 6: ...ree motion of switch Pump starts and stops too often 1 Water is back flowing into basin from discharge pipe 1 Install check valve 2 Switch is defective 2 Replace switch 3 Check valve not functioning properly or leaking 3 Be sure check valve is installed and operating properly Replace check valve if necessary Pump shuts off and turns on independently of switch trips thermal overload protection 1 Ex...

Page 7: ...intain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence or use of inappropriate chemicals or additives in the water c to normal maintenance services and the parts used in connection with such service d to units which are not installed in accordance with normal applicable local codes ordinances and good trade practices and e if the ...

Page 8: ...15 mounting screw M4 0 7x6 case o ring 115x4 NBR 3 Base Kit 025388 Includes pump base screws M5 0 8x15 4 Cap Kit 025385 Includes cap screws M6 1 0x15 GND screw M4 0 7x6 0 case o ring 115x4 NBR cap with handle guard and plug nameplate screw M3x1 34 switch to case screws switch 5 Float Kit 025381 Includes guide rod guide strap float REPAIR PARTS WIRING DIAGRAM 3 L1 L2 1 2 1 2 3 4 RUN O L MOTOR BLUE ...

Page 9: ...16 2020 All rights reserved ...