1
© Copyright 2014 Zoeller Co. All rights reserved.
2” INLET / HIGH HEAD
DRAIN PUMP SYSTEMS
MODELS 105-0010, 135-0005
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
FM2170
0114
Supersedes
0703
Notice to Installer: Instructions must remain with installation.
MODEL:_______________________
DATE CODE: __________________
DATE INSTALLED: _____________
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.
DO NOT
remove the test plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials
should be retained for future reference.
1.
To reduce the risk of electrical shock,
a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) and in accordance
with National Electrical Code and local codes.
(SEE WARNING BELOW)
2.
Make certain that the receptacle is within the reach of the
pump’s power supply cord.
DO NOT USE AN EXTENSION
CORD. Extension cords that are too long or too light do not
deliver sufficient voltage to the pump motor. But more impor
-
tant, they could present a safety hazard if the insulation were
to become damaged or the connection end were to fall into the
sump.
3.
Testing for Ground.
As a safety measure, each electrical outlet
should be checked for ground using an Underwriters Laboratory
Listed circuit analyzer which will indicate if the power, neutral
and ground wires are correctly connected to your outlet. If they
are not, call a qualified electrician.
4.
For Added Safety.
Pump must be connected to a 3-prong
grounded outlet interrupter device (ground fault circuit inter-
rupter).
5.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP
FROM ITS POWER SOURCE BEFORE HANDLING.
Single
phase pumps are supplied with a 3-prong grounded plug to help
protect you against the possibility of electrical shock.
DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND
PIN
. To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected
by a ground fault circuit interrupter (GFCI) in accordance with
national electrical code and local codes.
6. Installation and checking of electrical circuits and hardware
should only be performed by a qualified licensed electrician.
7. Risk of electric shock - These pumps have not been investigated
for use in swimming pool areas.
8. According to the state of California (Prop. 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
1. Check to be sure your power source is adequate for handling
the voltage requirements of the motor, as indicated on the pump
or basin plate.
2. Make sure the pump electrical supply circuit is equipped with
fuses or circuit breakers of proper capacity. A separate branch
circuit is recommended, sized according to the National Electri-
cal Code for the current shown on the pump name plate.
3. All plumbing (discharge and vent lines) must be installed to meet
local codes. Unit must be vented.
DO NOT USE AN AUTOMATIC
PLUMBING VENT DEVICE SIMILAR TO A “PRO-VENT”
.
Some states require this product to be installed by a licensed
plumber.
4. Repair and service should be performed by Zoeller Pump
Company Authorized Service Station only.
5. CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY
CYCLING OF PUMP.
6. Dewatering pumps are not designed or intended for handling
raw sewage.
7. Maximum operating temperature for 105-0010 and 135-0005
Drain Pumps must not exceed 130° F (54° C).
8. For health reasons, do not unplug, turn off, or disable pump
and use pump tank system as a way to fill up a sink or laundry
tray, etc.
SEE BELOW FOR LIST OF WARNINGS
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
REFER TO WARRANTY ON PAGE 2.
NOTE: Pumps with the “UL” mark and pumps with the “US” mark
are tested to UL Standard UL778. CSA Certified pumps are
certified to CSA Standard C22.2 No. 108.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.