background image

Quick Access Cassette System

Unlike other competitive automatic pool cleaners, the Zoom has the Quick Access Cassette System. This unique feature allows almost
instantaneous access to the one moving part –  the Diaphragm.

Large foreign objects, such as children’s toys, tree branches and rocks, should be removed manually from your pool prior to operating
an automatic pool cleaner. In the event a foreign object does not get manually removed and a blockage occurs, the Quick Access
Cassette System allows you the opportunity to remove the blockage or check the Diaphragm for damage in minutes at poolside.

DIAPHRAGM REMOVAL

Holding the hull assembly in one hand, unscrew the cassette (Step 1) and remove (Step 2). Holding the cassette at each end, unscrew
the cassette pipe from the Diaphragm chamber two full turns (Step 3). Grasp the lip of the Diaphragm and pull the Diaphragm out
(Step 4). The inner pipe will be attached and will make a loud noise. Pull the Diaphragm off of the inner pipe, leaving the retaining
ring on the Diaphragm (Step 5), and inspect for blockage or cuts. Remove blockage and rinse. Do not use sharp objects as damage to
Diaphragm may occur. If replacement parts are needed, contact technical service at 1-888-786-7797 for an authorized warranty station.

DIAPHRAGM ASSEMBLY

Prior to reinstalling the Diaphragm, rinse the Diaphragm and inner extension pipe thoroughly to remove any grit or algae. Attach the
Diaphragm to the inner extension pipe using the retaining ring (Step 6). Slide the inner extension pipe into the Diaphragm chamber. Pressing
on the underside of the Diaphragm’s ridges, push the Diaphragm into the chamber (Step 7). Holding the cassette at each end, tighten the
cassette pipe until snug, but do not overtighten. (Step 8). Insert the cassette assembly into the hull assembly and tighten (Step 9).

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Step 7

Step 8

To maintain quality, performance and increase the lifespan of your Zodiac Zoom, please do the following:

1.

Thoroughly clean the skimmer basket, pump basket and pool filter on a regular basis. 

Always disconnect the hose from the

skimmer before backwashing.

2.

REMOVE THE CLEANER BEFORE SUPER CHLORINATING OR ADDING POOL CHEMICALS.

Reinstall the Zodiac

Zoom when the imbalance is corrected or after a minimum of 4 hours from super chlorination. Chemical damage is not covered
under warranty.

3.

NEVER COIL THE HOSE

when the cleaner is removed from the pool. A coiled hose can be straightened with hot water or by

laying it on a warm pool deck for several hours.

INCORRECT

CORRECT

X

4. Remove disc and store it flat during the off-season. Store the cleaner head in a warm and dry place.

ZODIAC ZOOM

CARE AND MAINTENANCE

Step 9

Summary of Contents for Zoom

Page 1: ...318 1 45 Degree Elbow 1 41 2 Connector 11 Hose Lengths 1 Aboveground Valve Cuff 1 Pool Pulse 1 Disc The following parts are included with your Zodiac Zoom Model W83371 OWNER S MANUAL 1 Wheel Deflector...

Page 2: ...ITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO EACH COMPONENT OF THE ZODIAC ZOOM ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY WITH RESPECT TO SUCH COMPONENT SOME STATES DO NOT...

Page 3: ...vacuum line with the hose sections provided Water flows through the diaphragm of the cleaner at a rate of 14 to 19 gallons per minute Diverting or re directing the return inlets downward breaks up the...

Page 4: ...If the eyeball is difficult to adjust insert a screwdriver inside the eyeball and gently adjust downward If the return inlets cannot be pointed downward then you MUST install Zodiac return line diver...

Page 5: ...l Follow the instructions below for your specific model Model number is stated on the manual cover MODEL W01099 Slide the wheel deflector onto the cuff of the first hose section that connects to the c...

Page 6: ...female end of the hose Note You may not need to use all or you may need more hose sections depending upon your pool size SKIMMER WALL VACUUM FITTING SKIMMER WALL VACUUM FITTING FOR CENTER INSTALLATION...

Page 7: ...aner The Flowkeeper Valve comes preset at the setting required for your cleaner There are a total of three setting options The lower the setting number the lower the flow to the cleaner head Should re...

Page 8: ...as a diagnostic tool when the cleaner isn t running properly IDEAL TOO HIGH TOO LOW If the flow is in the low range review the installation procedures A dirty pool filter or clogged basket is usually...

Page 9: ...stuck on ladder Use Pool Pulse to insure proper flow Remove ladder if possible Install large wheel deflector Cleaner flips over Use Pool Pulse to insure proper flow Contact Tech Services for local war...

Page 10: ...Line Diverter Use to replace standard 2B W90155 directional inlet eyeballs for 2 return inlet 3 W26705 The Leaf Catcher with 41 2 Hose Connector Use when heavy debris or leaf situations exist 3 W46155...

Page 11: ...zed warranty station DIAPHRAGM ASSEMBLY Prior to reinstalling the Diaphragm rinse the Diaphragm and inner extension pipe thoroughly to remove any grit or algae Attach the Diaphragm to the inner extens...

Page 12: ...4 W74000 Compression Ring 5 W83382 Diaphragm Chamber 6 W83312 Hull Assembly 7 W69039 Footpad 8 W83300 Scalloped Disc 9 W56525 Threaded Inner Extension 10 W81600 Diaphragm Retaining Ring 11 W69698 Long...