34
Press the Connection button at the back of the control panel to enter the Connection mode. Press
the connect button at the back of the motion sensor or trigger the sensor (by moving in front of it).
Installation
Avoid mounting the detector close to windows, air conditioner, heater, refrigerator, oven, sunshine
and places where the temperature changes fast or where the air steam flows frequently.
If two detectors are installed in the same detection scope, adjust the location to avoid interferences
and false alarms.
Fix the bracket on the wall with screws and attach the detector to the bracket. Adjust the bracket to
change the detection distance and angle. It is recommended to mount the detector 2m from the
ground.
Top
Bottom
Ground
Top view
Side view
The detector is more sensitive to cross movements than vertical movements.
Testing
A. After the installation, turns the detector on. After one minute of self-testing, press the test button,
walk in the scope of detection and watch the LED indicator to make sure the detector is working.
B. The LED indicator blinks once when body movement is detected.
C. Adjust the detector angle to achieve the best detection performance.
Detection Scope
Top view
Side view
Specifications