To keep your TRi Unit in the best possible condition it is recommended
regular maintenance should be performed.
INSPECTING AND CLEANING THE ELECTRODE
In areas that experience calcium hardness the TRi electrode will benefit
from cleaning.
To clean your electrode:
1. Switch off the filter pump and chlorine generator, close necessary valves
and unplug the cell terminal cap.
2. Unscrew the retaining ring and
remove the electrode. If calcium
buildup is present, immerse the
electrode in cell cleaning solution
without immersing the terminals.
3. If you do not use commercial
cleaning solution, you can mix your
own by carefully adding one (1)
part of Hydrochloric (Muriatic) acid
to ten (10) parts water. Stronger
solutions will shorten terminal life.
4. Allow the cleaning solution to dissolve the calcium deposits for about
10 minutes. Dispose of the cleaning solution at an approved Council
Depot and never into storm water or sewage drains.
6. Rinse the electrode in clean water and re-fit the electrode in the cell
housing.
7. Replace the cell head and plug
assembly and reset valves and
switches. Turn pump and TRi on.
8. Confirm chlorine output and
settings on the power pack. Timer
settings will be automatically
retained.
MAINTENANCE