9
Check that the red indicator light on the switch (viewed from the side) is positioned to setting No. 3 (see image ).
0 1 2 3 4 5 6
6 5 4 3 2 1 0
3
If necessary, use the pool valves to adjust the flow rate so that the indicator light is in position 3.
•
When installing in a pool with a single skimmer, the flow rate is controlled by the flow regulation valve. The red
indicator light must be in position 3.
•
When installing in a pool with multiple skimmers, leave the valve of the skimmer connected to the hose open, then
gradually close the other skimmer until the indicator light reaches position 3.
•
When installing on a suction port, leave the suction line open and gradually close the skimmer line until the flow rate
reaches the adjustment position 3.
If the flow rate is in the low zone, between 0 and 2
(see image ):
•
Check and clean the pool filter and strainers if necessary.
•
Check that the valves controlling the suction lines are correctly placed in the open position.
•
Increase the flow rate on the automatic flow regulation valve (see image )
.
0 1 2 3 4 5 6
6 5 4 3 2 1 0
0 - 2
If the flow rate is in the high zone, between 4 and 6
(see image ) :
•
If the appliance is connected to the suction port, gradually close the valve until the flow rate reaches position 3.
•
Reduce the flow rate on the automatic flow regulation valve (see image )
.
•
Slightly open the bottom plug hole to reduce the flow rate a little more.
0 1 2 3 4 5 6
6 5 4 3 2 1 0
4 - 6
(+) Increase the flow rate
(-) Reduce the flow rate
EN