5
❷ Installati on
2.1 I Preparing the pool
2.1.1 Water balance
It is essenti al that the pool water balance is controlled and adjusted before installing the appliance. Making
sure that the pool water balance is correct from the very start will reduce the likelihood of encountering
problems on the fi rst days of operati on or during the season the pool is in use.
Even though it is an automati c regulati on system, it is essenti al to carry out regular water analyses
to check the water balance parameters.
Unit
Recommended
values
To increase
To decrease
Test frequency
(during the
season)
pH
/
7.2 – 7.4
Use the appliance in
"alkaline" dosage mode
and/or increase the set
point.
Use the appliance in
"acidic" dosage mode
and/or decrease the
set point.
Weekly
Free
chlorine
mg/L
or ppm
0.5 – 2
Add chlorine (manually
or using an automated
system)
Stop the release or
producti on of chlorine
Weekly
TA
(alkalinity
or buff er
capacity)
°f (ppm)
8 – 15
(80 – 150)
Add alkalinity corrector
(Alca+ or TA+)
Add hydrochloric acid
Monthly
HL
(hardness
level)
°f (ppm)
10 – 30
(100 – 300)
Add calcium chloride
Add a scale
sequestering agent
(Calci-) or carry out
decarbonati on
Monthly
Cyanuric
acid
(stabiliser)
mg/L
or ppm
< 30
/
Parti ally empty the
pool and refi ll it
Quarterly
Metals
(Cu, Fe,
Mn…)
mg/L
or ppm
± 0
/
Add a metal
sequestering agent
(Metal Free)
Quarterly
EN