 3.3 Calibrating the sensor(s)

• 

To  operate  accurately  and  reliably,  the  sensors  must  be  calibrated  before  using  the  power  pack  with  the 

module. To maintain maximum effi  ciency of the unit, we recommend calibrati ng at least once every 2 months 

during the period the swimming pool is being used.

• 

Ensure the sensors are cleaned before calibrati on (see «4.1 Cleaning the sensor(s)»). 

• 

Confi rm that the power pack is plugged in, 

• 

Stop the pool pump and isolate the sensors by closing any valves, so as to be able to remove the sensors safely. 

• 

Disconnect the BNC cable from the top of each sensor then remove them (unscrew) from the POD. Then reconnect the 

BNC cable to the sensors. 

• 

Rinse the end of the sensors with clean water and shake them to remove excess water. Do not touch or wipe the glass 

bulb at the end of the sensors.

• 

Put the pH sensor into a sample of the pH7.5 buff er soluti on supplied.

• 

Put the ACL sensor into a sample of the 700 mV buff er soluti on supplied.

• 

Leave  the  sensors  immersed  for  about  1  minute  to  obtain  a  reliable 

measurement.

• 

Press 

 or 

 the use the 

 or 

 keys to display "CALIB. PH" or "CALIB. PH\ACL", 

• 

then press 

 or 

.

• 

Use the

or

 keys to display "CALIBRAGE PH" (pH Link and Dual Link) or " CALIBRAGE ACL" (Dual Link only) then 

press 

 or 

.

Note the measured value: 

• 

pH = 'X.X'

 

-

If the value is greater than 8.2 or less than 6.4: the sensor is dirty or has been damaged during transport. Clean the 

pH sensor (see “4.1 Cleaning the sensor(s)”) then repeat the above steps. If the problem persists, contact your reseller.

 

-

If the value is between 6.4 and 8.2, press 

 or 

 to begin calibrati on. The procedure takes about 15 seconds.

          

           

 

-

When calibrati on is fi nished, check that the value displayed equals 7.5, otherwise repeat the calibrati on.

          

• 

ACL = 'XXX'

 

-

Start the calibrati on procedure by pressing

 or 

, the procedure lasts about 15 seconds,

          

        

 

-

If the value is 700: calibrati on is correct,

 

-

If the value is not 700: repeat the calibrati on steps. If the problem persists, clean the sensor, see “4.1 Cleaning the 

sensor(s)”,

 

-

Press 

 or 

 or wait 30 seconds to exit.

Summary of Contents for pH Link

Page 1: ...H0493700 C 2018 02 More documents on www zodiac com Instructions for installation and use English pH regulation Redox regulation Translation of the original instructions in french EN...

Page 2: ...automatically void the warranty Do not spray insecticide or any other chemical in ammable or non in ammable in the direction of the appliance as this may damage the body and cause a re Zodiac heat pum...

Page 3: ...Installing the pH Link or Dual Link module 5 2 3 Installing the POD Kit 5 3 Use 8 3 1 Activating the module 8 3 2 Display 8 3 3 Calibrating the sensor s 9 3 4 Adjusting the set point s 10 3 5 Setting...

Page 4: ...counterweight securing clip PTFE tape and stoppers suction injection hose 5 meters Buffer solution pH 7 5 Buffer solution 700 mV 1 2 Technical specifications pH Link module Dual Link module Supply vo...

Page 5: ...essential that the pool water balance is controlled and adjusted before installing the appliance Making sure that the pool water balance is correct from the very start will reduce the likelihood of e...

Page 6: ...sensor holding POD Kit and the pH minus injection pipe have been installed see 2 3 3 Installing the pH minus injection line 2 3 Installing the POD Kit The sensor holding POD Kit is a single assembly...

Page 7: ...ligned and tighten the locking ring rmly hand tighten only pH sensor Flow controller Water circulation direction pH minus injection ACL sensor A badly installed sensor may give false readings and caus...

Page 8: ...nstallation rinse the end of the sensor with tap water and shake off excess water For a restart after wintering clean the sensor see 4 1 Nettoyage de la des sonde s then calibrate it before installing...

Page 9: ...made in the cap and put the ceramic counterweight and threaded locking nozzle on the end Ensure that ALL connections are correct and watertight before operating the pH Link or Dual Link module Replac...

Page 10: ...sor into a sample of the 700 mV buffer solution supplied Leave the sensors immersed for about 1 minute to obtain a reliable measurement Press or the use the or keys to display CALIB PH or CALIB PH ACL...

Page 11: ...e chlorine production potential decrease the ACL set point Dual Link module only We recommend that you check the free chlorine level in the pool a few days after the module is installed to determine i...

Page 12: ...stopped immediately press or Con rm that the pump is primed pH minus solution will be visible in the translucent pipes To prime the peristaltic pump more quickly it may be necessary to repeat these st...

Page 13: ...2 glass of water Always pour the hydrochloric acid into the water The reverse method can lead to acid projections Once cleaning is complete dispose of the solution according to the standards in e ect...

Page 14: ...s Check the pH in the pool Calibrate or replace the pH sensor The pH minus container is empty Replace the container The peristaltic pump is not primed Test the peristaltic pump The pH sensor is dirty...

Page 15: ...e sensor see 4 1 Cleaning the sensor s If the problem continues contact your reseller To cancel the PH ERROR and ACL ERROR messages press or for 3 or 4 seconds when the message appears The other codes...

Page 16: ...erie BP 90023 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number...

Reviews: