background image

H03620

00.D2.EN

 

 

2013/03

 

 

3

 

1.3

 

Operating

 

conditions

 

 

Operating

 

range:

 

 

air

 

temperature

 

of

 

between

 

5

 

°C

 

and

 

38

 

°C

 

for

 

standard

 

models,

 

 

air

 

temperature

 

of

 

between

 ‐

8

 

°C

 

and

 

38

 

°C

 

for

 

TSR

 

models,

 

 

water

 

temperature

 

of

 

between

 

10

 

°C

 

and

 

32

 

°C,

  

 

 

Maximum

 

temperature

 

of

 

32°C

 

to

 

protect

 

the

 

pool

 

liner.

  

The

 

TSR

 

version

 

also

 

features

 

a

 

de

icing

 

function

 

by

 

using

 

forced

 

ventilation

 

or

 

reversed

 

cycle.

 

 

1.4

 

Technical

 

specifications

 

 

PFP

 

Voltage

 

Power

 

input*

    

Power

 

output*

 

Nominal

 

current

 

input*

 

COP*

kW

 

kW

 

A

 

6M

 

230V

50Hz

 

1.4

 

6.8

 

6.7

 

4.7

 

8M

 

230V

50Hz

 

1.7

 

7.6

 

7.9

 

4.5

 

11M

 

230V

50Hz

 

2.2

 

10.4

 

10.3

 

4.7

 

11T

 

400V

50Hz

 

2.2

 

10.5

 

4.25

 

4.8

 

13M

 

230V

50Hz

 

2.88

 

13.9

 

13

 

4.8

 

11M

 

TSR

 

230V

50Hz

 

2.2

 

10.7

 

10

 

4.9

 

11T

 

TSR

 

400V

50Hz

 

2.2

 

10.5

 

4.4

 

4.8

 

15M

 

TSR

 

230V

50Hz

 

3.6

 

15.7

 

16

 

4.5

 

15T

 

TSR

 

400V

50Hz

 

3.6

 

15.7

 

7.4

 

4.5

 

 

*

 

with

 

ambient

 

air

 

at

 

+15

 

°C,

 

pool

 

water

 

at

 

26

 

°C,

 

and

 

relative

 

humidity

 

of

 

70%

 

(according

 

to

 

French

 

standard

 

NF

414)

 

 

protection

 

class:

 

IP

 

24

 

 

refrigerant

 

gas:

 

R410A

  

 

refrigerant

 

charge:

 

see

 

product

 

information

 

plate

 

 

class:

 

I,

  

 

degree

 

of

 

pollution:

 

2,

  

 

overvoltage

 

category:

 

II

 

 

2.

 

Installation

 

 

 

Do

 

not

 

take

 

grip

 

on

 

the

 

outer

 

casing

 

to

 

pick

 

up

 

the

 

device,

 

hold

 

the

 

base.

 

 

2.1

 

Access

 

to

 

the

 

technical

 

compartment

 

 

    

             

            

 

 

2.2

 

Selecting

 

an

 

installation

 

site

 

 

 

The

 

device

 

must

 

be

 

installed

 

outdoors

 

and

 

there

 

must

 

be

 

adequate

 

open

 

space

 

surrounding

 

it

 

(see

 

§2.4).

 

 

 

the

 

heat

 

pump

 

must

 

be

 

installed

 

at

 

a

 

certain

 

distance

 

from

 

the

 

pool

 

so

 

as

 

to

 

avoid

 

exposure

 

to

 

water

 

splashes.

 

The

 

appropriate

 

distance

 

should

 

be

 

defined

 

according

 

to

 

the

 

national

 

electrical

 

standards

 

that

 

apply

 

in

 

the

 

country

 

of

 

installation

 

(for

 

France:

 

3.5

 

meters).

 

 

the

 

heat

 

pump

 

must

 

not

 

be

 

installed:

  

near

 

a

 

source

 

of

 

heat

 

or

 

inflammable

 

gas,

  

near

 

a

 

road/passage

 

where

 

there

 

is

 

a

 

risk

 

of

 

water

 

and

 

mud

 

splashes,

  

facing

 

a

 

strong

 

wind,

  

with

 

the

 

vent

 

facing

 

toward

 

a

 

permanent

 

or

 

temporary

 

obstacle

 

(window,

 

wall,

 

hedge,

 

etc…),

 

it

 

must

 

be

 

at

 

least

 

4

 

meters

 

from

 

any

 

potential

 

obstacle.

  

 

Summary of Contents for PF Premium 11T

Page 1: ...EN PF Premium 11M TSR 11T TSR 15M TSR 15T TSR 6M 8M 11M 11T 13M Instructions for installation and use English H03620 00 C 2012 02 374274014 01 More languages on www zodiac poolcare com...

Page 2: ...sically and mentally who are familiar with the operating instructions by reading the user guide Individuals who do not satisfy these requirements must not handle the device so as to avoid exposure to...

Page 3: ...malfunctions 12 5 3 FAQ 12 6 Product registration 13 Information included at the end of the manual wiring diagrams dimensions description compliance certificate 1 Information before installation 1 1 G...

Page 4: ...dity of 70 according to French standard NF 414 protection class IP 24 refrigerant gas R410A refrigerant charge see product information plate class I degree of pollution 2 overvoltage category II 2 Ins...

Page 5: ...ack of the packing box 2 4 Hydraulic connections Check the direction of the pipework connection see Dimensions in the appendix The connection include a 50 PVC rigid pipe from a by pass on the swimming...

Page 6: ...utside of the European community with an outer diameter between 9 and 18 mm use the cable gland to run the supply cable into the device 2 5 2 Connections the electrical supply cable must not be expose...

Page 7: ...re is below the required temperature thanks to a dry contact without max I polarity 8 A between terminals 1 2 alarm option to connect a relay to the alarm contact thanks to a dry contact without max I...

Page 8: ...ent ambient air temperature adequate inadequate operation indicator During heating or air conditioning On standby until operating command received defrost indicator Defrost in progress On off button b...

Page 9: ...s on stand by press on for 3 seconds will appear for 2 seconds and for 3 seconds and the water and set point temperatures will be displayed a 2 minute delay will start set the required water temperatu...

Page 10: ...vacuate the impurities which could block it clean the outside of the unit with a solvent free product A specific PAC NET cleaning kit is available as an optional extra see 4 3 check that the water con...

Page 11: ...performances 4 3 Available accessories Name PAC NET Wintering cover Remote control unit Technical room kit Representation 4 4 Recycling This symbol means that your device must not be thrown in the bi...

Page 12: ...r Switch the power supply off or press Water flow rate sensor defect ST4 Sensor out of order or disconnected connector J8 white on plate A1 Replace or reconnect the sensor Switch the power supply off...

Page 13: ...n error message appearing The heat pump does defrost cycles from time to time This is normal if the outdoor temperature is below 10 C The evaporator is clogged Clean the evaporator see 4 1 the heat pu...

Page 14: ...hecked all of the above points contact your installer Where should my water treatment system be positioned with respect to the heating system The water treatment system chlorinator salt chlorinator et...

Page 15: ...H03620 00 D2 EN 2013 03 1 Wiring diagram PFP 6M 8M 11M 13M...

Page 16: ...H03620 00 D2 EN 2013 03 2 PFP 11T...

Page 17: ...H03620 00 D2 EN 2013 03 3 PFP 11M TSR...

Page 18: ...H03620 00 D2 EN 2013 03 4 PFP 15M TSR...

Page 19: ...H03620 00 D2 EN 2013 03 5 PFP 11T TSR 15T TSR...

Page 20: ...ard for display C1 Fan capacitor C2 Compressor capacitor C3 Filter D1 Progressive starter H Defrost resistance HP High pressure switch LP Low pressure switch J1 Flow rate switch M1 Fan motor M2 Compre...

Page 21: ...EN 2013 03 7 Dimensions and description Base Front pannel cowl Technical door Back pannel Post Grid Regulator 1 water pool inlet 1 water pool outlet Evaporator Stuffing box PFP weight 6 51 8 52 11 63...

Page 22: ...t your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barth l my d Anjou cedex Fra...

Reviews: