background image

H03620

00.D2.EN

 

 

2013/03

 

 

1

 

 

 

 

Read

 

this

 

manual

 

carefully

 

before

 

installing,

 

maintaining,

 

or

 

repairing

 

this

 

device!

 

 

The

 

symbol

 

indicates

 

important

 

information

 

that

 

must

 

be

 

taken

 

into

 

account

 

in

 

order

 

to

 

avoid

 

risk

 

of

 

personal

 

injury

 

and/or

 

damage

 

to

 

the

 

appliance.

 

 

The

 

symbol

 

 

indicates

 

useful

 

information.

 

 

   

Warnings

 

 

 

Our

 

products

 

may

 

be

 

subject

 

to

 

change

 

without

 

notice

 

as

 

part

 

of

 

our

 

continuous

 

improvement

 

policy.

  

 

Exclusive

 

use:

 

pool

 

water

 

heating

 

(must

 

not

 

be

 

used

 

for

 

any

 

other

 

purpose).

 

 

The

 

device

 

must

 

be

 

installed

 

by

 

a

 

qualified

 

technician

 

according

 

to

 

the

 

manufacturer’s

 

instructions

 

and

 

in

 

compliance

 

with

 

local

 

regulations.

 

The

 

installer

 

is

 

responsible

 

for

 

the

 

correct

 

installation

 

of

 

the

 

device

 

and

 

for

 

ensuring

 

compliance

 

with

 

local

 

regulations.

 

The

 

manufacturer

 

shall

 

not

 

be

 

held

 

liable

 

for

 

any

 

potential

 

issues

 

that

 

may

 

occur

 

as

 

a

 

result

 

of

 

failure

 

to

 

comply

 

with

 

local

 

standards

 

pertaining

 

to

 

installation.

 

 

This

 

appliance

 

must

 

be

 

handled

 

by

 

competent

 

and

 

qualified

 

personnel

 

(physically

 

and

 

mentally)

 

who

 

are

 

familiar

 

with

 

the

 

operating

 

instructions

 

(by

 

reading

 

the

 

user

 

guide).

 

Individuals

 

who

 

do

 

not

 

satisfy

 

these

 

requirements

 

must

 

not

 

handle

 

the

 

device

 

so

 

as

 

to

 

avoid

 

exposure

 

to

 

potentially

 

dangerous

 

parts.

 

 

In

 

the

 

case

 

of

 

device

 

malfunction:

 

do

 

not

 

attempt

 

to

 

repair

 

the

 

device

 

yourself,

 

call

 

your

 

installer.

 

 

Before

 

carrying

 

out

 

any

 

operation

 

on

 

the

 

device,

 

ensure

 

that

 

the

 

power

 

supply

 

is

 

off,

 

that

 

the

 

device

 

is

 

decommissioned,

 

and

 

that

 

the

 

"heating

 

priority"

 

function

 

is

 

de

activated.

 

 

Before

 

reconnecting

 

any

 

component,

 

check

 

that

 

the

 

voltage

 

indicated

 

on

 

the

 

device

 

corresponds

 

to

 

the

 

mains

 

voltage.

 

 

If

 

any

 

safety

 

device

 

is

 

removed

 

or

 

shunted,

 

the

 

warranty

 

will

 

automatically

 

be

 

void.

 

This

 

will

 

also

 

apply

 

if

 

parts

 

are

 

replaced

 

with

 

parts

 

acquired

 

elsewhere

 

than

 

in

 

our

 

stores.

 

 

Do

 

not

 

vent

 

R410A

 

fluid

 

into

 

the

 

atmosphere:

 

R410A

 

is

 

a

 

fluorinated

 

greenhouse

 

gas

 

that

 

is

 

covered

 

by

 

the

 

Kyoto

 

Protocol,

 

with

 

a

 

Global

 

Warming

 

Potential

 

(GWP)

 

=

 

1975

  ‐ 

(see

 

regulation

 

on

 

fluorinated

 

greenhouse

 

gases,

 

European

 

Community

 

Directive

 

EC

 

842/2006).

 

 

Incorrect

 

installation

 

may

 

cause

 

serious

 

damage

 

and/or

 

personal

 

injuries

 

(potentially

 

death).

 

 

Keep

 

the

 

device

 

out

 

of

 

the

 

reach

 

of

 

children.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PF Premium 11T

Page 1: ...EN PF Premium 11M TSR 11T TSR 15M TSR 15T TSR 6M 8M 11M 11T 13M Instructions for installation and use English H03620 00 C 2012 02 374274014 01 More languages on www zodiac poolcare com...

Page 2: ...sically and mentally who are familiar with the operating instructions by reading the user guide Individuals who do not satisfy these requirements must not handle the device so as to avoid exposure to...

Page 3: ...malfunctions 12 5 3 FAQ 12 6 Product registration 13 Information included at the end of the manual wiring diagrams dimensions description compliance certificate 1 Information before installation 1 1 G...

Page 4: ...dity of 70 according to French standard NF 414 protection class IP 24 refrigerant gas R410A refrigerant charge see product information plate class I degree of pollution 2 overvoltage category II 2 Ins...

Page 5: ...ack of the packing box 2 4 Hydraulic connections Check the direction of the pipework connection see Dimensions in the appendix The connection include a 50 PVC rigid pipe from a by pass on the swimming...

Page 6: ...utside of the European community with an outer diameter between 9 and 18 mm use the cable gland to run the supply cable into the device 2 5 2 Connections the electrical supply cable must not be expose...

Page 7: ...re is below the required temperature thanks to a dry contact without max I polarity 8 A between terminals 1 2 alarm option to connect a relay to the alarm contact thanks to a dry contact without max I...

Page 8: ...ent ambient air temperature adequate inadequate operation indicator During heating or air conditioning On standby until operating command received defrost indicator Defrost in progress On off button b...

Page 9: ...s on stand by press on for 3 seconds will appear for 2 seconds and for 3 seconds and the water and set point temperatures will be displayed a 2 minute delay will start set the required water temperatu...

Page 10: ...vacuate the impurities which could block it clean the outside of the unit with a solvent free product A specific PAC NET cleaning kit is available as an optional extra see 4 3 check that the water con...

Page 11: ...performances 4 3 Available accessories Name PAC NET Wintering cover Remote control unit Technical room kit Representation 4 4 Recycling This symbol means that your device must not be thrown in the bi...

Page 12: ...r Switch the power supply off or press Water flow rate sensor defect ST4 Sensor out of order or disconnected connector J8 white on plate A1 Replace or reconnect the sensor Switch the power supply off...

Page 13: ...n error message appearing The heat pump does defrost cycles from time to time This is normal if the outdoor temperature is below 10 C The evaporator is clogged Clean the evaporator see 4 1 the heat pu...

Page 14: ...hecked all of the above points contact your installer Where should my water treatment system be positioned with respect to the heating system The water treatment system chlorinator salt chlorinator et...

Page 15: ...H03620 00 D2 EN 2013 03 1 Wiring diagram PFP 6M 8M 11M 13M...

Page 16: ...H03620 00 D2 EN 2013 03 2 PFP 11T...

Page 17: ...H03620 00 D2 EN 2013 03 3 PFP 11M TSR...

Page 18: ...H03620 00 D2 EN 2013 03 4 PFP 15M TSR...

Page 19: ...H03620 00 D2 EN 2013 03 5 PFP 11T TSR 15T TSR...

Page 20: ...ard for display C1 Fan capacitor C2 Compressor capacitor C3 Filter D1 Progressive starter H Defrost resistance HP High pressure switch LP Low pressure switch J1 Flow rate switch M1 Fan motor M2 Compre...

Page 21: ...EN 2013 03 7 Dimensions and description Base Front pannel cowl Technical door Back pannel Post Grid Regulator 1 water pool inlet 1 water pool outlet Evaporator Stuffing box PFP weight 6 51 8 52 11 63...

Page 22: ...t your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barth l my d Anjou cedex Fra...

Reviews: