sEcTION 5 – TROuBlEshOOTINg
PROBlEM
chEcKs
sOluTIONs
your PAcER™
does not reach the
shallow end of the
pool or moves in a
fixed pattern.
Is the hose long enough?
Add more sections of hose.
Is the hose affected by the
return flow?
Adjust the return outlet
towards the bottom of the
pool to make sure that the jet
of water does not influence
the direction of the
Zodiac
®
Hose.
Are the hose lengths
straight?
Make sure that the hose
lengths are in good condition.
Never roll up/coil hoses.
your PAcER™
climbs above the
water level.
Is there too much suction?
Check that the Auto Weir
Valve is not blocked by leaves
and preventing the water from
flowing through the Auto
Weir Valve.
your PAcER™ does
not climb the walls
easily.
Is there sufficient suction?
Make sure the filter is clean.
Adjust Auto Weir Valve
setting (Refer to correct
settings page 8)
your PAcER™ falls
on its side.
Is the float damaged?
Return to your nearest pool
shop for checking.
Is the counterweight firmly
fixed to the main body?
Lack of equilibrium inside the
floating system. The PACER™
should be returned for
checking.