8. Disconnect the air pressure switch wiring (yellow/black) and the gas
valve wiring (brown) by unclipping the terminals from the PC board.
9. Using a standard pipe wrench, disconnect the gas train at the union.
10. Using a 7/16ʺ wrench, remove four (4) nuts with fl at washers and star
washers to disconnect the blower.
11. Remove two (2) screws to disconnect the air pressure switch from
the blower (Figure 2).
Figure 2. Remove Air Pressure Switch