background image

2

EN

External connecti ons: what products should be connected?

The chlorinator must be protected by a circuit breaker of the same type as that used for a fi lter pump (for example a 

fi ltrati on control panel).

If the chlorinator is powered by a fi ltrati on control panel, the ti mers must be manually set to 24/7 mode. The electrolyser 

manages all ti mers and must receive a conti nuous power supply.

12 - 24 V contact

230 V contact

RS485 cable (supplied 

with the pump)

230 V power 

supply

230 V power 

supply

All types of auxiliary 

device 

12 - 24 V

All types of auxiliary 

device 

230 V

FloPro™ VS

All fi lter pump models

Transformer for lighti ng, 

booster pump, etc.

maximum 8 A

Transformer for lighti ng, 

booster pump, etc.

maximum 8 A

Variable-speed pump

maximum 8 A

Single-speed pump or 

variable 3-speed pump of 

type FloPro™ e3.

maximum 8 A

Connecti ng a fi lter pump (depending on the model)

The chlorinator can power and control the fi lter pump.

In such a case, the chlorinator must be powered via an electrical protecti on that is calibrated for a fi lter pump.

Possible controls: 

- For a single-speed pump (SSP): ON/OFF with 2 ti mers, 

- For a FloPro™ VS variable-speed pump (VSP): ON/OFF/RPM with 4 ti mers.

(see installati on manual for the Zodiac™ 

FloPro® VS fi lter pump)

RS485

 Cable 

(supplied with the 

pump)

Power supply 

230 V

230 V power 

supply

FloPro™ VS

All fi lter pump models

Variable-speed pump

maximum 8 A

Single-speed pump or 

variable 3-speed pump of 

type FloPro™ e3.

maximum 8 A

GREEN

YELLOW

BLACK

RED

RED

BLACK

YELLOW

GREEN

(Terminal block at the level of the FloPro™ VS pump)