2
EN
External connecti ons: what products should be connected?
The chlorinator must be protected by a circuit breaker of the same type as that used for a fi lter pump (for example a
fi ltrati on control panel).
If the chlorinator is powered by a fi ltrati on control panel, the ti mers must be manually set to 24/7 mode. The electrolyser
manages all ti mers and must receive a conti nuous power supply.
12 - 24 V contact
230 V contact
RS485 cable (supplied
with the pump)
230 V power
supply
230 V power
supply
All types of auxiliary
device
12 - 24 V
All types of auxiliary
device
230 V
FloPro™ VS
All fi lter pump models
Transformer for lighti ng,
booster pump, etc.
maximum 8 A
Transformer for lighti ng,
booster pump, etc.
maximum 8 A
Variable-speed pump
maximum 8 A
Single-speed pump or
variable 3-speed pump of
type FloPro™ e3.
maximum 8 A
Connecti ng a fi lter pump (depending on the model)
The chlorinator can power and control the fi lter pump.
In such a case, the chlorinator must be powered via an electrical protecti on that is calibrated for a fi lter pump.
Possible controls:
- For a single-speed pump (SSP): ON/OFF with 2 ti mers,
- For a FloPro™ VS variable-speed pump (VSP): ON/OFF/RPM with 4 ti mers.
(see installati on manual for the Zodiac™
FloPro® VS fi lter pump)
RS485
Cable
(supplied with the
pump)
Power supply
230 V
230 V power
supply
FloPro™ VS
All fi lter pump models
Variable-speed pump
maximum 8 A
Single-speed pump or
variable 3-speed pump of
type FloPro™ e3.
maximum 8 A
GREEN
YELLOW
BLACK
RED
RED
BLACK
YELLOW
GREEN
(Terminal block at the level of the FloPro™ VS pump)