Page 23
Page 22
eXO
®
| Installation Manual
8.6 Programming/Timers
The controller has two internal operating timers.
The timers are used to define the length of time for
the filter pump to operate, and the length of time
for the Salt Water Chlorinator (SWC) to produce
chlorine. This offers the user the advantage of
running their variable speed pump longer at lower
flow rates, without having the chlorinator producing
the whole time.
In order to complete the timer program, it is
necessary to enter and validate both ON and
OFF times. If no timer is set, the filtration and / or
chlorination will run continuously
The filtration operating times must be sufficient to
correctly treat the water.
Example
- single speed pump:
In Season filtration time: 8-10 hours per day.
Off Season filtration time: 4-5 hours per day.
Example
- variable speed pump (when running at
lower speeds):
In Season filtration time: 12-14 hours per day
In Season SWC time: 8-10 hours per day
Off Season filtration time: 10-12 hours per day
Off Season SWC time: 4-5 hours per day
Once validated, The SWC will adopt the same
timers as the filtration pump. The chlorination time
must be equal or shorter than the filtration time.
The device will not accept a SWC timer longer than
or outside the programmed filtration time.
8.6.1
Reset Timers
1. Press
.
2. Use
to select “Programming”
then press .
3. Use
to select “Reset Timers” then press .
The selected timers will be reset to 00:00.
8.6.2
Operation With an External Timer
In order for the controller to operate with an
external timer. All controller programs must be
cleared and the device must be on. After the
connection to the external timer is made, turn the
controller off then back on again.
8.6.3
Single Speed Programming
1. Press
.
2. Use
to select “Programming”
then press .
3. Use
to select “Filter Pump” then press .
4. Use
to select “Pump Timer 1” or “Pump
Timer 2” then press .
5. Use
to select the hour for the filtration on
time then press .
6. Use
to select the minutes for the filtration
on time then press .
7. Use
to select the hour for the filtration off
time then press .
8. Use
to select the minutes for the filtration
off time then press .
9. Press
to exit.
<
-PROGRAMMING
-LOW MODE
-SLAVE MODE
MAIN MENU
<
-FILTER PUMP
-SWC
-AUX/LIGHTS
PROGRAMMING
<
-PUMP TIMER 1
-PUMP TIMER 2
FILTRATION TIMER
<
-PUMP 1 ON
-PUMP 1 OFF 12:30
04:30
FILTRATION TIMER
10. When a filtration program has been confirmed
the letter “P” is displayed on the top right of
the screen.
23:04 ON
P
Manual activation of the device (pressing
)
takes priority over the timer. If no filter pump is
connected, the controller will only start chlorination.
If a single speed filter pump has been connected
the filter pump will start along with chlorination.
If a variable speed pump filter pump has been
connected the filtration pump will run along with the
chlorination at it’s set RPM 1 speed. All programs
will still be valid and will resume normal operation
the next cycle.