3) Plug it into the power point but do not
turn on yet
8) Fit the cell housings around pipe (and
spacer with 40mm pipe) as shown
7) 40mm diameter pipe, use spacer as
shown. Spacer not required on 50mm pipe
4) Ensure placement of Ei cell on pipe is
no more than 1.5m from power pack
Spacer used for
40mm pipe only
Less than
1.5m
Do not install
past 45 degrees
NOTE:
If the inlet/outlet lines are close to each other your Ei cell will need to be mounted
on an angle. Holes should be drilled on an angle no more than 45 degrees
5) Invert the lower housing of the cell
enclosure to mark the holes for drilling
6) Drill holes using the holesaw provided
and ensure holes are clean and smooth
7
To prevent the possibility of hazardous over-chlorination, the Ei has a
built-in safety shutdown. If the Ei is manually turned ON (with no timers set),
and left on, chlorine generation will automatically turn OFF after 24 hours. The
Ei can be turned ON as normal after this time.
NOTE: If using the Ei with an external timer – the 24 hour timer is reset
whenever power is cut to the Ei.
CHLORINATOR REVERSAL
The Zodiac Ei chlorine generator has a reverse polarity cell. This means
that every 5 hours the cell will switch its polarity to help prevent any build up
of calcium on the cell plates. This is sometimes referred to as self cleaning.
During the transition between changing its polarity there is a 5 minute wait
time when the cell will not produce any chlorine. Dont be alarmed, once it has
changed polarity it will continue to make chlorine.
‘** CLEANING **’ will be displayed on the screen during the 5 minute ‘WAIT’
period (the output level indicator will remain as set during the CLEANING
period.
24 HOUR SAFETY
TIMEOUT
16
Smooth
edges
The water flow must
follow the direction
of the arrows