H0435000.A - EN - 2013-11
3
1. Information before installing
1.1 General delivery terms and conditions
All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The latter must make
written reserves on the transporter’s delivery documents if damage during transport is discovered (confirmed by
registered letter to the transporter within 48 hours).
1.2 Contents
x1
x1
x1
x1
x1
x1
1.3 Technical specifications
Power supply voltage
230Vac-50Hz
Electric output
9 W
Protection index
IP65
Maximum peristaltic pump flow
1.5L/hr
Maximum counter pressure at the injection point
1.5 bar
Redox sensor tolerance
5 bar / 60 °C / maximum speed 2m/s
Measurement scale
0 - 1 000 mV (±10 mV)
Redox sensor response time
< 15 seconds
2. Installation
2.1 Preparing the pool
2.1.1 Water balance
It is essential that the pool water balance is controlled and adjusted before installing the appliance. Making sure pool
water balance is correct from the start will reduce the likelihood of problems occurring during the first days of operation
or during the pool usage season.
Even if it is an automatic regulation system, it is essential to carry out regular water analyses to check the water
balance parameters.
Unit
Recommended
values
To increase
To lower
Test frequency
(during the season)
pH
/
7.2 – 7.4
Use pH+ or a pH
regulation
Use pH- or a pH
regulation
Weekly
Free Chlorine
mg/L or ppm
0.5 – 2
Increase the Redox
set point or use the
«Boost» Mode
Lower the Redox set
point
Weekly
TAC
(alkalinity or
buffer power)
°f (ppm)
8 – 15
(80 – 150)
Add alkalinity
corrector
(Alca+ or TAC+)
Add hydrochloric acid
Monthly
HL
(hardness
level)
°f (ppm)
10 – 30
(100 – 300)
Add calcium
chloride
Add a scale sequestrant
(Calci-) or carry out
decarbonation
Monthly