background image

/ 10 

8

 

PRESSURE 

 

The correct pressure for the buoyancy tube and the keel is 240 mb / 3,4 PSI   

(green area of the 

pressure indicator). 

 

If your boat is not equipped with a 

ACCESS

 pressure indicator, we recommend that you purchase one 

from your Dealer. This will permit a quick and efficient control of the pressure during inflation. Without 

a  pressure  indicator,  stop  inflating  when  the  foot-pump  gets  difficult  to  operate,  and  the  boat  is 

« hard » (you should not be able to bend the cone ends).

 

 

Ambient temperature of air and water 

Ambient temperature 

tubes’ internal pressure 

have an effect on the boat’s internal 

+1°C / +1,8°F 

+4 mb / 0,06 PSI 

pressure 

-1°C / -1,8°F 

-4 mb / 0,06 PSI 

 

Therefore, it is important to anticipate:  

Because of temperature variations (especially when this variation is important between the beginning 

and the end of the day, in hot areas) check and adjust the pressure in the inflated compartments by 

inflating  or  deflating.  Be  sure  that  pressure  remains  within  the  recommended  zone,  between  220 

mb/3,10 PSI and 270 mb/3,85 PSI (green area).

 

 

 

RISK OF UNDERPRESSURE 

 

 

EXAMPLE: 

Your  boat  is  in  direct  sunlight  on  the  beach  (temperature  =50°C/122°F)  at 

recommended  pressure  (240  mb/3,4  PSI).  after  putting  it  in  the  colder  water  (temperature 

=20°C/68°F), the internal temperature and pressure of the tubes will both drop (up to         120 mb/1,7 

PSI)  and

  YOU  WILL  HAVE  TO  INFLATE  AGAIN

  until  you  regain  the  lost  pressure  due  to  the 

difference  in  temperatures.  Therefore,  a  loss  of  pressure  at  the  end  of  the  day  when  ambient 

temperature drops is perfectly normal. 

 

 

NOTICE :

 

Proper inflation is critical to the performance of the boat. It is the pressure in 

the tubes that gives your boat the necessary rigidity to perform well. Under-

inflation causes improper flexing of the tubes which will result in stress and 

chafe 

 

 

RISK OF OVERPRESSURE 

 

 

EXAMPLE: 

Your  boat  is  inflated  to  the  recommended  pressure  (240  mb/3,4  PSI)  at  the 

beginning of the day (low ambient temperature =10°C/50°F). Later in the day, your boat is in direct 

sunlight  on  the  beach  or  on  a  yacht’s  deck  (temperature  =50°C/122°F).  Internal  temperature  of  all 

inflated  compartments  can  then  increase  and  reach up to 70°C/158°F (especially for dark-coloured 

tubes). The consequence will be a doubling of previous pressure (480 mb/6,8 PSI).

 YOU WILL THEN 

HAVE TO DEFLATE

 until you reach the recommended pressure. 

 

 

CAUTION

 

WHEN  YOUR  BOAT  IS  OVER  INFLATED,  PRESSURE  BECOMES  TOO 
STRONG  FOR  THE  INFLATABLE  STRUCTURE,  AND  COULD  CAUSE  A 
BREAK IN THE FABRIC ASSEMBLY 

 

IN CASE OF OVERPRESSURE 

 

STANDARD VALVE (A): 

Free some air by pushing on the 

diaphragm (1) with a blunt 

object. 

Beware not to fold down the 

diaphragm.  

 

SEMI-RECESSED VALVE (B): 

Deflate by pressing the spring 

loaded button.

 

A

1

 

 

Summary of Contents for CADET ROLL UP 200

Page 1: ...Tome 2 Volume 2 Teil 2 Tomo 2 CADET CADET ROLL UP 200 240 260 CADET SOLID 260 285 310 340 ZT03744 Edition 17...

Page 2: ...COMMENDATIONS THAT MUST BE OBSERVED VOLUME 2 DEALS WITH TECHNICAL SPECIFICATIONS AND ASSEMBLY PROCEDURE OF THE BOAT AND ITS EQUIPMENT VOLUME 2 TECHNICAL SPECIFICATIONS ASSEMBLY PROCEDURE ZODIAC CADETS...

Page 3: ...f the boat to the correct pressure 7 8 INFLATION PRESSURE 7 Install the oars 9 ASSEMBLY OF EQUIPMENT CHECK ON UNPACKING CAUTION DO NOT USE A SHARP TOOL The pack must contain 1 buoyancy tube Cadet Roll...

Page 4: ...Check that the floorboard is correctly fitted in the angles 7 Flatten the apex by standing on it in the boat and pulling the lifelines to prevent the fabric being pinched fig 2 8 Assemble the stringer...

Page 5: ...10 4 ASSEMBLY fig 1 A 1 2 3 4 5 6 fig 1 B a angle b floorboard c tube d bottom a b c d fig 2 1 2 3 4 5 6 fig 3 fig 4 7 8 1 2 3 4 5 7 9...

Page 6: ...LL UP 200 240 INSTALL THE SLATTED FLOOR Boat deflated slide the slats in their pockets starting by the closest to the transom If the slats are difficult to insert lubricate it with liquid soap CADET R...

Page 7: ...the valve insert from its protection Unscrew the valve cap Screw the valve support onto its base screw it tight but without exaggeration not to deteriorate the screw thread and check that the valve ca...

Page 8: ...the pump hose end piece Inflate pressure 240 mb refer to PRESSURE section making sure that each compartment is equal When correctly inflated the internal bulkheads a are not visible NEVER COMPLETELY I...

Page 9: ...al temperature and pressure of the tubes will both drop up to 120 mb 1 7 PSI and YOU WILL HAVE TO INFLATE AGAIN until you regain the lost pressure due to the difference in temperatures Therefore a los...

Page 10: ...10 E N G L I S H 9 ASSEMBLY OF STANDARD EQUIPMENT TO ASSEMBLE AND INSTALL THE OARS THE REMOVABLE SEAT EXCEPT C 200 ROLL UP Install the seat before the boat is totally inflated Clic...

Page 11: ...in buoyancy tube A fold the cones onto the transom then roll up the boat around the transom C Start again if you feel there is still some air left in the tubes A B buoyancy tube floor tube deflated C...

Page 12: ...N DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION BESCHREIBUNG BESCHREIBUNG BESCHREIBUNG BESCHREIBUNG DESCRIZIONE DESCRIZIONE DESCRIZIONE DESCRIZIONE DESCRIPCI N DESCRIPCI N DE...

Page 13: ...6 1 4 1 6 1 4 1 6 1 4 1 6 1 6 1 8 Capacit Capacity Capacit Kapazit t Capacidad ISO 2 3 3 1 3 1 4 5 5 1 Maximum Kg 190 250 300 370 400 450 750 lb 419 551 661 815 881 992 1653 Kg 19 23 30 35 36 39 49 lb...

Page 14: ...du manuel chapitre Conseils de navigation La portata massima autorizzata calcolata in conformit alla normativa ISO In condizioni di massimo carico si raccomanda di navigare con particolare prudenza P...

Page 15: ...n slats 200RU 240RU Pagliolato a listelli 200 RU 240 RU herausnehmbarer Lattenboden 200 RU 240 RU tabillas extraibles 200 RU 240 RU Plancher d roulant C260 RU Rolling floor C260 RU pagliolato avvolgib...

Page 16: ...IV IV DDESCRIPTION BESCHREIBUNG DESCRIZIONE DESCRIPCI N CADET SOLID 260 S 285 S 310 S 340 S 1 2 14 3 4 13 12 5 6 7 15 8 9 CADET ROLL UP 200 RU 240 RU 260 RU 6 17 16 9 18 10 8 10 11 18...

Page 17: ...2 chemin de la Val Priout 31450 AYGUESVIVES FRANCE Cadets Solid Roll up Code ZT03744 Edition 17 Copyright Z NAUTIC 2015 Z NAUTIC S A S U au capital de 7 000 000 Euros R C S PARIS 812 206 340...

Reviews: