%\SDVV3OXPELQJ,QVWUXFWLRQV
7KHPD[LPXPÀRZUDWHIRUWKHFHOOLVJSP,IÀRZUDWHH[FHHGVJSPWKHFHOO0867EHSOXPEHGRQE\SDVV
VHH)LJXUH$FRQWUROYDOYHPXVWEHLQVWDOOHGWRUHJXODWHWKHÀRZWKURXJKWKHFHOO,WFDQEHLQVWDOOHGRQWKHLQOHWVLGH
RIWKHFHOORUEHWZHHQWKHLQOHWDQGGLVFKDUJHVLGHRIWKHE\SDVVSLSLQJ7KHSURSHUÀRZZLOOEHDFKLHYHGE\DGMXVWLQJWKH
handle of the valve until the red “No Flow” light has turned off and all large air bubbles are cleared from the cell.
Do not install
past 45 degrees
)LJXUH ([DPSOHRI%\SDVV,QVWDOODWLRQ
)LJXUH ([DPSOHRI$OWHUQDWLYH,QVWDOODWLRQ
$OWHUQDWLYH,QVWDOODWLRQ:KHQ3LSHLV2EVWUXFWHG
,IWKHRQO\VXLWDEOHOHQJWKRISLSHLVREVWUXFWHGVXFKDVRQDPXOWLSRUWYDOYHRIWHQIRXQGRQDVDQG¿OWHULWLV
DFFHSWDEOHWRµOHDQ¶WKHFHOORYHUXSWRDPD[LPXPRIGHJUHHVVHH)LJXUH0DUNWKHIHHGHUKROHVLQWKHVDPH
angle that the cell will be leaning to ensure that you drill in the right position.
The cell must be installed as the last piece of
equipment in the circulation plumbing system
just before the pool
Cell
Heater
Pump
Power Pack
Filter
Pool Intake
Spa Intake
Spa Return
Pool Return
To common
power source
Control Valve Installation Options
,QVWDOORQWKHLQOHWVLGH
RIWKHYHVVHO
,QVWDOOEHWZHHQWKHLQOHW
DQGGLVFKDUJHVLGHRI
E\SDVVSOXPELQJ
Wate
r Flo
w