![Zodiac Pool Systems andy AquaPure EI Series Installation And Operation Manual Download Page 10](http://html1.mh-extra.com/html/zodiac-pool-systems/andy-aquapure-ei-series/andy-aquapure-ei-series_installation-and-operation-manual_3955026010.webp)
Page 10
6HFWLRQ
,QVWDOODWLRQ,QVWUXFWLRQV
Before you begin your installation, please check that you have the right tools and a suitable location to install the
power pack and cell. Please ensure that you have read and understood the Important Safety Instructions section.
0DWHULDOVDQG7RROV
Installation Materials Furnished
Tools Needed for Installation
3LSH6SDFHUIRUòLQPPSLSH
+ROH6DZ
6FUHZ6HWLQFOXGHVZDOOSOXJV
,QVWDOODWLRQDQG2SHUDWLRQ0DQXDO
&RUGOHVV'ULOORU3RZHU'ULOO
LQPP+DPPHU'ULOO%LWRQO\QHFHVVDU\WRGULOOLQWR
EULFNRUFRQFUHWH
3HQFLORU0DUNLQJ3HQ
3HDG6FUHZGULYHURU3HDG'ULOO%LW
WARNING
EQUIPMENT UNDER PRESSURE:
$OZD\VWXUQSXPSRIISULRUWRLQVWDOOLQJRUVHUYLFLQJWKH-DQG\$TXD3XUH
(LFKORULQHJHQHUDWLQJGHYLFH<RXUSXPS¿OWHUV\VWHPLVRSHUDWHGXQGHUSUHVVXUHDQGWKHSUHVVXUHPXVWEH
UHOHDVHGEHIRUH\RXEHJLQZRUN3OHDVHVHH\RXUSXPS¿OWHURZQHU¶VPDQXDOIRUIXUWKHULQVWUXFWLRQV
WARNING
7KH-DQG\$TXD3XUH(LFKORULQHJHQHUDWLQJGHYLFHPXVWEHLQVWDOOHG
KRUL]RQWDOO\ZLWKWKHFHOODERYHWKHSLSHWRDYRLGEXLOGXSRIÀDPPDEOH
JDVHVZKLFKFDQUHVXOWLQ),5(25(;3/26,21
)LJXUH
,QVWDOODWLRQ5HTXLUHPHQWV
IWP0$;
Cell
Power
Pack
1
ѿIWP0,1
,QVWDOODWLRQ5HTXLUHPHQWV
WARNING
FOR YOUR SAFETY:
7KLVSURGXFWPXVWEHLQVWDOOHGDQGVHUYLFHGE\DSURIHVVLRQDOSRROVSDVHUYLFHWHFKQLFLDQ
7KHSURFHGXUHVLQWKLVPDQXDOPXVWEHIROORZHGH[DFWO\)DLOXUHWRIROORZZDUQLQJQRWLFHVDQGLQVWUXFWLRQVPD\
UHVXOWLQSURSHUW\GDPDJHVHULRXVLQMXU\RUGHDWK,PSURSHULQVWDOODWLRQDQGRURSHUDWLRQZLOOYRLGWKHZDUUDQW\
The installation requirements for the Jandy AquaPure Ei chlorine
generating device are as follows:
The power pack must be be installed at least 5 ft. (1.5 m) vertically off
the ground.
,QWKH86
the power pack must be be installed at least 5 ft. (1.5 m) from
the inside wall of your swimming pool or spa; in Canada, the power
pack must be be installed at least 10 ft. (3 m) from the inside wall of your
swimming pool or spa.
7KHFHOOPXVWEHLQVWDOOHGRQDѿIWPKRUL]RQWDOOHQJWK
RISLSHDIWHUWKHKHDWHUVSXPSVDQG¿OWHUVDVWKHODVWSLHFHRI
equipment in the circulation plumbing system just before the pool (see
Figure 3).
7KHFHOOPXVWEHLQVWDOOHGQRPRUHWKDQIWP
from the power
pack (see Figure 3).