background image

Warnings & Tips for Best Performance

NOTE:

 

System designed to increase water temperature by 

25°-30°F. If water exiting showerhead is not hot enough, 

place showerhead in same water container as pump & 

recirculate water for a few minutes. 

WATER PRESSURE:

 

If water flow/pressure drops or water 

temperature increases, immediately point showerhead 

away from body & safely turn off heater until proper water 

pressure is regained.

WATER DRIPPING FROM BOTTOM:

 Water dripping 

from the bottom of the heater during use is normal. This 

is condensation and will occur every time the heater is on, 

especially in humid climates.

LOW WATER PRESSURE

:

 

Zodi suggests using only new 

batteries. Weak batteries or vapor lock will cause pump to 

perform poorly. If new batteries are not available, reduce 

distance between pump and showerhead by elevating 

water container on table. With heater OFF and cool, initiate 

water flow with weak batteries by applying suction to 

showerhead. Check hoses for kinks. Check debris screen 

at end of pump - twist off pump cap and rinse out foam 

screen. Shake pump under water to release vapor lock. 

Pump & battery case are NOT covered by warranty. 

CONNECTING 16.4 oz DISPOSABLE PROPANE 

CYLINDER:

 

This product uses propane gas. Propane gas 

can explode, burn and is a fire hazard. Propane gas is 

heavier than air and can accumulate in low areas. Never 

store propane indoors or near any heat source, near any 

open flames, near any pilot light, in direct sun light, near any 

ignition source or where temperatures exceed 120° F. Do 

not refill disposable propane cylinders. Dispose of empty 

gas cylinders in a safe and responsible manner. Always 

attach & detach gas cylinder outdoors away from flames, 

other ignition sources & only when heater is cool to touch. 

If propane cylinder has a protective cap, remove protective 

cap. Check that top of propane cylinder and fittings are 

clean and free of dirt and debris. Turn off propane gas valve, 

twist propane cylinder clockwise into gas valve at bottom 

of heater. Check propane cylinder is tight and is not leaking 

at connection by testing for leaks with soapy water (see 

below).

TESTING FOR GAS LEAKS:

 

To ensure safety, test for 

leaks before using shower. Never use flame to check for 

leaks. With gas valve turned completely off and propane 

connected to shower, apply soapy water (1 part liquid 

detergent to 3 parts water) around area where the gas 

valve connects to the propane. Bubbles near propane 

connection indicate leaks. If bubbles are present, ensure 

the propane connection is not crossthreaded. Check 

that propane cylinder connection is tight. Repeat process 

(test for leaks) until no leaks are present. If leaks persist, 

do not use product, but contact Zodi.

COLD WATER TEMPERATURE:

 To heat colder water 

(especially at higher altitudes), place showerhead in the 

same water container as the pump and recycle water until 

it reaches a suitable temperature. When heater is turned all 

the way up, heat may be lost as flames begin to exit exhaust 

holes at the top of the system. In this case, hotter water can 

be produced by turning the gas valve down. BTU output 

varies and may reach up to 10,000 BTU dependent upon 

altitude, atmospheric conditions, outside temperature, and 

propane level and temperature. Cold and empty propane 

tanks decrease performance. Also, new batteries generate a 

higher flow of water, causing water temperature to be slightly 

lower for the first few minutes of operation.

WARNING - SYSTEM GETS HOT DURING USE:

 

Allow system to cool before handling. Do not place any 

itemsincluding towels, soap & shampoo on or near heater. 

Keep children & pets clear of heater when operating. Operate 

only outdoors in well ventilated areas clear of any flammable 

vapors & material.

SHOWER HOSES:

 

Once hoses are attached, they can remain 

on the shower. If hose becomes brittle or becomes loose, 

cut off about 2 inches of the hose and reattach hose to the 

fitting. Both hoses must be tightly and completely connected 

to the entire length of hose barbs on shower and pump.

REMOVING PROPANE FROM UNIT:

 Only attach or detach 

gas cylinder outdoors, away from flames and ignition 

sources, after the heater has cooled completely. To remove 

propane from your shower, turn shower on its side and 

twist propane tank counter-clockwise until fully removed 

from shower. Replace protective cap on propane tank. 

Store propane outdoors. Read manufacturer’s directions on 

propane cylinder for other warnings. 

CLEANING RECOMMENDATIONS:

 Clean outside of shower 

housing using a soft damp cloth. Clean inside of hoses and 

heating system by placing pump in clean water with baking 

soda and turning the pump on for 1 minute. Rinse after with 

clean water. Never submerge heater or battery case in water.

STORAGE:

 

Remove propane cylinder from heater before 

transport or storage. For added protection, wrap heater 

in towel before storing in storage bag. To prevent freeze 

damage to coil in cold climates, drain all water from coil 

by blowing on showerhead for 10 seconds. Store heater 

in storage case to prevent dust and insects from clogging 

burner during storage. Torn bags, freeze damage and pumps 

are not covered by warranty. Always store propane outdoors 

- see propane warnings above.

Warranty Disclaimer:

 Due to the harsh conditions product 

may be exposed to, there is no warranty on electronic 

components including piezo push button & battery operated 

pump. Never modify, alter or use with any part or device not 

approved by Zodi.

Reviews: