Specification 

MODEL 

 

 

IG500-12-C 

IG1000-12-C 

IG2000-24-C 

IG 1000-24-C 

CAPACITY   

VA/W 

500VA/300W 

1000VA/600W 

2000VA/1200W 

1000VA/600W 

INPUT 

Nominal Voltage 

110/120VAC or 220/230/240VAC 

Voltage Range 

90-145VAC or 170-280VAC (Narrow Range) 

  50-145VAC or 90-280VAC (Wide Range)   

OUTPUT 

Voltage 

120VAC or 230VAC 

 

 

Voltage Regulation (Batt. Mode) 

+10% / -18% 

 

 

Frequency 

50Hz or 60Hz 

 

 

Frequency Regulation (Batt. 
Mode) 

+/-0.1 Hz 

 

 

Output Waveform 

Modified Sine-wave 

BATTERY & 
CHARGER 

Charger Current 

10Amp +/- 1Amp  10 Amp +/- 1Amp  10Amp +/- 1Amp 

10A +/-1Amp 

DC Voltage 

12V +/- 0.2V 

12V +/- 0.2V 

24V +/- 0.4V 

24V +/- 0.4V 

Overcharge Protection 

14.5V +/- 0.3V charger stops and 

fault 

29V +/- 0.6V charger stops and   

fault 

TRANSFER 
TIME 

Typical 

10-20ms typical(narrow range); 40ms max(wide range) 

EFFICIENCY 

AC to AC 

>95% 

DC to AC 

>80% 

INDICATOR 

AC Mode 

Green lighting 

Battery Mode 

Yellow lighting 

Battery Charging Mode 

Green flashing every 2 seconds 

Overload 

Red flashing every 0.5 second 

Fault 

Red lighting 

AUDIBLE 
ALARM 

Low Battery at Battery Mode 

Sounding every 2 seconds 

Overload 

Sounding every 0.5 second 

Fault 

Continously sounding 

PROTECTION 

Full Protection 

Discharge, overcharge, and overload protection 

PHYSICAL 

Dimension (DxWxH) mm 

224 X 255 X 80 

Net Weight (kgs) 

1.7 

2.1 

2.3 

2.1 

ENVIRONMENT 

Operating Environment 

0- 40

°

C, 0-90 % relative humidity (non-condensing) 

Noise Level 

Less than 55dB 

 

 

 

 

* Product specifications are subject to change without further notice. 

 
 
 
 
 
 
 
 
 

Version:00

 

614-00005-00 

Summary of Contents for IG500-12-C

Page 1: ...USER MANUAL...

Page 2: ...ted for 75 o C or higher and should be no less than 10AWG gauge The inner diameter of the copper ring terminal which is used to connect battery cables to Inverter DC terminals should be no less than 6...

Page 3: ...he battery set via charging system In UPS mode Inverter automatically convert battery energy into AC power for backing up the connected devices Features l Automatic line to battery switchover l Select...

Page 4: ...eries are connected press this button and Inverter will turn on automatically and works in mains mode or inverter mode according to input AC source s status When press this button again Inverter will...

Page 5: ...s below Remark Off mode charging is same 7 Load level definition the tolerance is 10 rating power When over load the mark will flicker every 1second status Battery voltage 12V 24V 1 2 3 4 CC CV Bat 13...

Page 6: ...t status Overload 1 Vout 195V 0 Off Output voltage RMS low 2 Off Short circuit 3 Off Fan locked 4 On 4 Off Battery voltage high 5 On 5 Off Overload 2 Vout 195V Pout 80 rated half wave load 6 On 6 Off...

Page 7: ...neral electrical appliance If you select this mode the Inverter operating voltage in Line mode is within 170 280Vac 90 145Vac with the same output voltage The line sensitivity is higher Hence you can...

Page 8: ...ter reboot Battery Connection Step 1 Pinch the bottom of DC input cover and Open it See Figure 4 Step 2 Following battery polarity guide located near battery terminal Place the battery cable ring term...

Page 9: ...ngly recommend that you should isolate the battery terminals before you start to operate the unit Please refer to below instruction for further information If you parallel more batteries to extend the...

Page 10: ...4VDC l Parallel battery connection When using multiple batteries in parallel each battery s voltage must be equal to the voltage of Inverter Nominal Input Voltage see specs AC Connection Before having...

Page 11: ...s and fault 29V 0 6V charger stops and fault TRANSFER TIME Typical 10 20ms typical narrow range 40ms max wide range EFFICIENCY AC to AC 95 DC to AC 80 INDICATOR AC Mode Green lighting Battery Mode Yel...

Reviews: