Flash programming the DigiMaster CW chip;
The CW chip in the latest DigiMaster Pro3 is now Flash updatable. To enter Flash update mode;
[1] Download and run the latest CW update from the website.
[2] Turn the interface OFF.
[3] Press and hold BOTH paddles keys closed and turn ON the interface, keep the paddles held for
approximately 5 seconds when the LED will turn ORANGE to indicate that the chip is in update mode.
The chips memory has now been cleared and the chip is waiting for the update.
[4] In the update software, select the port to which the CW keyer is normally attached.
[5] In the update software, click the button marked “Flash Update”.
[6] The led on the Pro3 will momentarily turn RED and then back to orange, the new code is being
sent to the chip.
[7] After approx 30 seconds the LED will flash RED twice to indicate that the code has been
successfully read. The LED will then switch back to GREEN and the update has been completed.