The gas conversion procedure for this range includes:
1. Pressure Regulator
2. Surface Burners
3. Flame Adjustment
The conversion is not finished if all steps are not completed.
Before performing the gas conversion, locate the package containing the
replacement nozzles, which has a number indicating its flow diameter printed on the
body. Consult the table below for matching nozzles to burners.
Save the nozzles removed from the range for future use.
Reference the diagrams below if your range was manufactured before May 2021.
To check, reference the rating label under the front edge of the range.
LPG: Liquid Propane Gas
NG: Natural Gas
INSTALLATION
PRESSURE REGULATOR
Since service pressure may fluctuate with local demand, every gas cooking
appliance must be equipped with a pressure regulator on the incoming service line
for safe and efficient operation.
• The pressure regulator shipped with the appliance has two female threads 1/2”
NPT. The regulator shall be installed properly in order to be accessible when the
appliance is installed in its final position.
• Manifold pressure should be checked with a manometer and comply with the
values indicated below.
Natural Gas->4.0”W.c.P
L P/Propane-> 10.0” W.c.P
• Incoming line pressure upstream from the regulator must be 1˝ W.C.P. higher
than the manifold pressure in order to check the regulator.
• The regulator used on this range can withstand a maximum input pressure of ½
PSI (13.8˝ W.C or 3.5kPa) If the line pressure exceeds that amount, a step down
regulator is required.
• The appliance, its individual shut-off valve, and the pressure regulator must be
disconnected from the gas line during any pressure testing of that system at
pressures in excess of ½ PSI (13.8˝ W.c or 3.5kPa).
Pressure Regulator
Before carrying out this operation, disconnect the appliance from gas
and electricity.
Gas conversion shall be conducted by a factory-trained professional.
WARNING
INSTALLATION
Gas Connection
Gas Connection
Appliance Tag Here