M.2CANFD
M.2 Interface CAN (FD) Card
©2022 Guangzhou ZLG Electronics Co., Ltd.
5
User Manual
1.3.2
Specifications
Table 1.2 Product specifications
Item
Specification
M.2CANFD
PCI-9820I
PCI-9840I
PCI-9820
Number of CAN
channels
2. circuits
2-way
4 cameras
2-way
Working voltage
3.3V±5%
Power
consumption
≤3W
Isolation voltage
2500VDC
Output terminal
2x1.25-3P connector, converted into 2xDB9 through the interface board
CAN baud rate
40Kbps - 1Mbps (CAN) 1Mbps - 5Mbps (CANFD acceleration)
Data receiving
capability
10,000 frames/second/channel (remote frame, single frame transmission)
Data sending
capability
4,000 frames/second/channel (remote frame)
Windows system
driver
Support
Support
Support
Support
Linux system
driver
Support
-
-
Support
Support
VxWorks driver
—
-
Support
Support
Dimensions
(length×width)
PCB dimensions (WLH): 22.0 x 80.0 mm x 5.6 mm;
PACK board size (WLH): 31.9 mm x 36.3 mm x 14.1 mm (the length does not
include DB9).
130 × 90 mm
130 × 90 mm
130 × 90 mm
Operating
temperature
-40°C ~ +85°C
Ambient humidity
10%-90% (no condensation)
Environmental
Requirements
Keep away from corrosive gas
1.3.3
Operating Temperature
The M.2CANFD interface card can work in an industrial-grade environment. Its
applicable operating temperature range: -40°C to +85°C. Using the interface card in too
low or too high ambient temperature will make it work abnormally and shorten its service
life.
1.4
Typical Applications
⚫
CAN(FD)-Bus network diagnosis and test;
⚫
Electric power communication network;
⚫
Industrial control equipment;
⚫
Vehicle network debugging;
⚫
Automotive electronics applications;