CANSwitch-AF2S2
High-Performance Dual-CAN to Fiber Switch User Manual
©2021 Guangzhou ZLG Electronics Technology Co.,Ltd.
35
User Manual
server. If the connection fails, the client continuously tries to establish a connection with
the TCP server based on the preset connection conditions. After establishing a TCP
connection with the TCP server, two-way data communication can be carried out. Figure
4.28 shows the communication establishment process.
Figure 4.28 Communication in TCP Client mode
Tip: In this mode, the TCP server IP address is determined by "Destination IP (see
Table 5.2)"; the TCP server port is determined by "Destination Port (see Table 5.2)".
There are six groups of valid "Destination Port" and "Destination IP". The device will
connect to the TCP server specified by the six groups of parameters in turn based on
the preset number of connections until the connection is successful.