4.2.2.
Wiegand Settings
On this page, you can set the work mode of the machine, Wiegand output interval, Wiegand data format,
RF parameters, card reading prompt, card reading interval and Wiegand output.
Descriptions:
Work Mode
Read always, that is, the machine reads the card after it is powered on.
Read by trigger, that is, when the purple line (int trigger line) is low, the
machine will read the card. At the same time, you can set the time for the
machine to read the card once triggered, ranging from 1 to 255 seconds.
Wiegand Output Time
The interval between the Wiegand data and the next Wiegand data
ranges from 200 milliseconds to 1 second.
Wiegand Format
Supports Wiegand 26, 34, 42, 50, 58, 66, 74, 82, 90, 98.
RF Settings
Set the RF power and RF frequency band for the module.
Reader Indicator
Set the machine reader card to beep or not.
Tag Reading Interval
Set the time between one card read and the next.
Wiegand Output Settings
Sets the machine's forward and inverted output of Wiegand data, and
from which bit to take.
Read Configuration
Read the machine's existing configuration.
Save Changes
After modifying the configuration, click
Save Changes
.