Wiegand Reader Connection

Note:

  485A  and  485B  can  be  connected  to  the  Barrier  gate  or  the  485  Reader, 

separately,  but  cannot  be  connected  to  the  gate  and  reader  at  the  same  time.

 RS485 Connection

 WD0

 WD1

485A
485B

WD0-OUT
WD1-OUT

INWD0

INWD1

GND

12V-OUT

Wiegand 

Reader

+12V

GND

 WD1

 WD0

Access 

Controller

485 Reader

+12V

GND

485+

485-

485A
485B

WD0-OUT
WD1-OUT

INWD0

INWD1

GND

12V-OUT

Summary of Contents for SpeedFace-V3L

Page 1: ...tallation Guide SpeedFace V3L Version 1 0 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual ...

Page 2: ...GLASS REFRACTION KEEP EFFECTIVE DISTANCE 0 3 2 5m KEEP DISTANCE 10ft 6 5ft window Device Installation Fix the backplate on the wall using wall mounting screws Attach the device to the backplate Fasten the device to the backplate with a security screw Attach the mounting template sticker to the wall and drill holes according to the mountingpaper 1 1 5m 2 4 3 ...

Page 3: ...ernet IP Address input the IP address and click on OK IP address 192 168 1 130 Subnetmask 255 255 255 0 Default IP address 192 168 1 201 Subnetmask 255 255 255 0 Connect the device and computer software over an Ethernet cable As shown in the examplebelow ZKBio Access Note In LAN the IP addresses of the server PC and the device must be in the same network segment when connecting to the ZKBio Access...

Page 4: ...he 485 Reader separately but cannot be connected to the gate and reader at the same time RS485 Connection WD0 WD1 485A 485B WD0 OUT WD1 OUT INWD0 INWD1 GND 12V OUT Wiegand Reader 12V GND WD1 WD0 Access Controller 485 Reader 12V GND 485 485 485A 485B WD0 OUT WD1 OUT INWD0 INWD1 GND 12V OUT ...

Page 5: ...Normally Closed Lock The NO LOCK normally unlocked when power on is connected with NO and COM terminals andtheNCLOCK normallylockedwhenpower on isconnectedwith NC and COM terminals TakeNCLockasanexamplebelow 1 Device not sharing power with the lock 2 Device sharing power with the lock Normally Closed Lock Normally Closed Lock GND DC12V FR107 Maximum 30V 3A input 12V DC12V GND DC12V FR107 12V NC CO...

Page 6: ...5 Download Center Scan the QR Code to download the User Manual Installation Guide and Quick Start Guide QR Code Download Center ...

Page 7: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2022 ZKTECO CO LTD All Rights Reserved ...

Reviews: