background image

3

+12V
GND

J19

485A

GND

J18

485B

How to enable 485 Reader Function?

1. Enable RS485 Reader Function: Press M/OK > Comm. > Serial Comm > Serial port ,

select [master unit].

2. Setting 485 Reader veri cation mode: Press M/OK > Access Control > Access Control Options

>Verify mode by RS485,to choose veri cation mode.

Description

Color

Power Out          +12V

Red

Ground                GND

Black

Wiegand In        IWD1

Green

Wiegand In         IWD0

White

Red LED               RLED

Blue

Green LED

GLED

Gray

Beep                     BEEP

Purple

+12V
GND

IWD1

IWD0

RLED
GLED
BEEP

J19

+12V

I

D

W 1

I

D

W 0

WD0

WD1

+12V

+12V

GND

GND

485A

485B

+12V

GND

GND

485+

485-

GND

GND

6 485 Reader Connection

7 Wiegand Card Reader Connection

Wiegand Card Reader

Summary of Contents for PA10

Page 1: ...PA10 Fingerprint Palm Terminal QUICK START GUIDE Version 1 0 Date August 2017 Time Attendance Access Control...

Page 2: ...igand In PIN LED Power Out 8 232 Weigand Out PIN RS485 RS 2 Power In PIN 6PIN Alarm Lock Exit Button Sensor Bell Auxiliary In Tamper Alarm Button 6PIN RS485 RS 232 Weigand Out Ethernet Port USB Slot R...

Page 3: ...J17 J21 AL AL 1 NC 1 COM 1 NO BUT GND SEN BELL BELL GND AUX GND AUX Ground GND Purple Auxiliary AUX Brown 2 5 Do not install the device in a place subject to direct sunlight humidity or dust 4 Wiring...

Page 4: ...Access Control Options Verify mode by RS485 to choose veri cation mode Description Color Power Out 12V Red Ground GND Black Wiegand In IWD1 Green Wiegand In IWD0 White Red LED RLED Blue Green LED GLE...

Page 5: ...r devices use a power supply with higher current ratings Description Color Power In 12V Red Ground GND Black GND 12V DC 12V GND J20 To connect device with a PC directly connect both devices with a str...

Page 6: ...not be set manually Display in Status Bar To set whether to display the network icon on the status bar Press M OK System Date Time to enter the Date Time interface Press M OK User Mgt New User to ente...

Page 7: ...wing conditions 1 The current unlock time should be in the effective time of user time zone or group zone 2 The group which user is must be in Combined Verification Access Control Options Set paramete...

Page 8: ...wet cloth If a ngerprint is too dry blow on the nger and retry 2 Fingerprint is veri ed but authorization keeps failing Check whether the user is restricted by door zone or time zone 3 Authorized but...

Reviews: