User Manual
OP1000 series
Applicable Models: OP1000/1200, 1011/1211, 1022/1222
Version: 1.0
Date: December 2018
Page 1: ...User Manual OP1000 series Applicable Models OP1000 1200 1011 1211 1022 1222 Version 1 0 Date December 2018...
Page 2: ...allation 4 3 1 Equipment installation condition and position 4 3 2 Cables installation 5 3 3 Equipment installation and fixing 6 3 4 Set up a warning line 6 4 Equipment wiring and debugging 7 4 1 Inte...
Page 3: ...304 housing anti corrosion and durable It serves as a carrier equipped with the direction indicator reader infrared sensor door lock and more It provides legal access to persons while eliminating ille...
Page 4: ...ormal open and there will not be alarm 6 It has the liquid crystal display function and can describe the channel operation in intuitive words 1 4 Electronic control system The electronic control syste...
Page 5: ...W 180 H 1000 Communication RS485 Input voltage AC100 240V 50 60Hz Input control signal Switching signal Output voltage DC 24V 5A DC 12V 3A Time of opening closing 5 s adjustable Passage rate Maximum...
Page 6: ...conditions The ground base must be concrete to ensure the expansion screws are firmly fixed If you do not have this condition please consult construction or decoration professionals about creating the...
Page 7: ...Figure 3 3 The input voltage of this machine is AC100 120V 200 240V and its master and slave are connected with a 6 core connection wire When installing this swing barrier turnstile you only need to c...
Page 8: ...3 3 Use a hammer drill to drill M12 screw holes and fix the screws accordingly Place the swing barrier turnstile according to the size and position as shown in the figure before installation and fixin...
Page 9: ...User Manual 7 4 Equipment wiring and debugging 4 1 Internal wiring diagram Figure 4 1 4 2 Master and slave wiring diagram The connection between the master and the slave is illustrated with red lines...
Page 10: ...lue DOWN to move a menu item downwards or decrease the value ENT to enter menu setting item or confirm the current modified value ESC to return to the previous menu or to cancel the current operations...
Page 11: ...et whether to trigger the alarm when reverse intrusion occurs The current value is xxx Press UP or DOWN to change the value then press ESC to return The default setting is enabled The setting is compl...
Page 12: ...modes available The working mode is the normal working mode of the machine while the factory reset mode is to restore brake parameters to default values The default value is 1 Device normally working...
Page 13: ...OP1000 series User Manual 11 menu press UP or DOWN to choose a menu item then press ENT to enter the interface and adjust such function or value...
Page 14: ...efore maintenance Check whether the plug is loose if yes tighten it Do not change the connection position Check whether the external power supply is exposed if yes timely wrap it Also check whether th...
Page 15: ......