Cautions
4.
LED Indicators and Wire Illustration
InBio
160
Installation and Connection Guide
Version: 1.3
Date: Nov., 2015
1) Meaning of LED indicators
:
LINK indicator (green): Constant light always indicates TCP/IP
communication is normal.
ACT indicator (yellow): Flashing indicates data is transmitting through TCP/IP communication.
EXT RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
PC RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
POWER
indicator (red):
Light always indicates the control panel is power on.
RUN
indicator (green): Flashing indicates that system is working normally.
CARD
indicator (yellow): Flashing indicates a card is punched on reader.
2) Recommended use of wires
:
3) The auxiliary input may be connected to infrared body detectors, alarm switches, etc.
4
The auxiliary output may be connected to door bells, alarms, etc.
)
5) State Indicators are connected to the panel box, that is power indicator, run status indicator and communication status indicator.
Power
Supply
Temper
Switch
After the following installation, fix the panel to the track first, and then install other
components .
Dissipation Hole
Control
Panel
Control
Panel
Panel
Track
Panel
Track
2
2
1
1
3) Install
other
components
2) Fix the box
1) Get through the thread hole
Interface
Wire Specification
Network cable
Maximum length
Power (A)
18AWG*2PIN
/
1.5M
Wiegand (B)
24AWG*6PIN
(6PIN, 8PIN, 10PIN for different
readers)
CAT-5 or above network cable, one
way DC impedance is less than 100
Ω
/KM
100M
Electric Lock (C)
18AWG*2PIN+24AWG*2PIN,
18AWG*2PIN for lock connection,
24AWG*2PIN
for
door
sensor
connection.
/
50M
Button (D)
24AWG*2PIN
/
100M
EXT485 (E)
20AWG*2PIN+24AWG*2PIN,
20AWG*2PIN
for
reader
power
supply,
24AWG*2PIN
for
RS485
communication
CAT-5 or above network cable, one
way DC impedance less than 100
Ω
/KM. In wire connection, +12V and
GND of power supply need to be
parallel and use double wires.
Share power with control panel: 100M
Use
independence
power
supply
(connect RS485 signal interface only):
1000M
Please note the following cautions. Mis-operation may lead to personal injury or
equipment failure:
1
)
Do not energize the system before installation is complete; never carry out
installation activities when the system is energized.
2
)
All peripheral devices must be grounded.
3
)
The conduits of wires under relay must be matched with metaled conduits, other wires
can use PVC conduits.
4
)
It is strongly recommended that the length of exposed part of any connection cable
should not be longer than 4 mm. Professional clamping tools may be used to avoid
unintentional contact of exposed wires to avoid short-circuit or communication failure.
5
)
It is recommended that card readers and buttons be installed at height of 1.4m-1.5m
above ground.
6
)
It is recommended to use the power supply for control panel, and external power
supply for each lock.
7
)
The appliance shall be installed and wired in accordance with national electrical
code and by qualified personnel only
Description of normal working state:
Connect the system to the power supply. If the system works properly, the POWER
indicator (red) is lit constantly and the RUN indicator (green) flashes.
Valve regulated lead-acid battery:
Constant voltage charge voltage regulation
Cycle use : 14.5V~14.9V(25)
Initial current: less than 2.88A
Standby use: 13.6V~13.8V(25)
Capacity: 12V, 7.2Ah/20hr
Battery Type: LC-RA127R2T1
Caution:
Do not charge in a gas tight container.
Do not short the battery terminals.
Do not incinerate
Flush with water at once if contact is made with
electrolyte (Acid)
Do not attempt to disassemble the battery.