background image

GND

GND

V

+

V

+

Normally Closed Lock

Normally Closed Lock

9

Lock Relay Connection 

10

The  system supports  both 

Normally  Opened  Lock

  and 

Normally  Closed  Lock

. The 

NO  Lock

  (Normally 

Opened when powered) is connected with '

NO

' and '

COM

' terminals, and the 

NC Lock

 (Normally Closed 

when powered) is connected with '

NC

' and '

COM

' terminals.

 

The power can be shared with the lock or  can 

be used separately for the lock

,

 as shown in the example with

 

NC Lock

 

below.

Device not sharing power with the lock

PC

PC

GND

GND

NC

NC

+12V DC

COM

COM

GND

Maximum

30V

2A

input.

FR107 Diode 

FR107 Diode 

TCP/IP

TCP/IP

Device sharing power with the lock

+12V

Do not reverse 
the polarity.

Do not reverse 
the polarity.

Summary of Contents for C2-260

Page 1: ...ation Guide C2 260 Metal Cabinet Version 1 0 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this...

Page 2: ...ttons be installed at height of 1 4m 1 5m above ground 6 It is recommended to use the power supply for control panel and external power supply for each lock 7 The appliance shall be installed and wire...

Page 3: ...2 Product Dimension 3 C2 260 Aux485 WR485 C2 260 Metal Cabinet 330 0mm 364 6mm 75 7mm...

Page 4: ...Cabinet 4 C2 260 Panel Heat Dissipation Hole Aux485 Power Supply Cable Conduit Power Indicator Punch Hole for cables Mounting Holes We recommend drilling the mounting plate screws into solid wood i e...

Page 5: ...4 5 Internal Wiring Diagram C2 260 Power Indicator Aux485 Power Supply L N G V V B B 12V Battery Prepared by the user...

Page 6: ...be connected externally to RS485 reader 4 Restore factory setting The NO 4 of DIP switch is OFF by default When it is moved up and down for three times within 5 seconds and nally returned to OFF posi...

Page 7: ...AUX4 DC12V AUX485 12V GND 485B 485A AUX1 GND AUX2 AUX3 GND AUX4 DC12V 485A 485B GND Notes 1 A C2 260 can connect to maximum two AUX485 modules 2 Each AUX485 module can connect to maximum four auxilia...

Page 8: ...ote 1 It s recommended to connect maximum four readers to one C2 260 2 A single RS485 reader interface can supply a maximum of 750 mA 12V current So the entire current consumption should be less than...

Page 9: ...8 Exit Button Connection 9 EXIT GND BUT K2S Exit Button...

Page 10: ...nd the NC Lock Normally Closed when powered is connected with NC and COM terminals The power can be shared with the lock or can be used separately for the lock as shown in the example with NC Lock bel...

Page 11: ......

Reviews: