BG500 Series Barrier Gate
User Manual
P a g e
|
18
Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Parameter Settings Description
Parameter
List of
menu
items
3m boom
parameter
value
4.5m boom
parameter
value
6m boom
paramete
r value
Opening speed adjustment: the larger
the value, the faster the gate opening
speed
L-1
80
60
60
Closing speed adjustment: the large
the value, the faster the gate closing
speed
L-2
70
50
50
Barrier boom in the place balance
adjustment(default)
L-3
12
12
12
Anti-smashing car reaction time
sensitivity adjustment(default)
L-4
30
30
30
Motor strength value
Adjustment(default)
L-5
70
70
70
Horizontal adjustment of barrier
boom
L-6
5
5
10
Test mode selection: 0 is manual,1 is
automatic (default)
L-7
0
0
0
Turn on the memory function: 0
means no memory; 1 means memory
and 4 indicates peak mode (default)
L-8
0
0
0
Vertical position adjustment of barrier
boom
L-9
5
5
8
Adjusting the deceleration stroke of
the first stage of opening barrier
L-L
40
40
30
Adjusting the deceleration stroke of
the first stage closing barrier
L-B
40
40
30
Anti-smashing car force adjustment
(default)
L-C
50
50
50
The forward and reverse running
settings of the barrier type,1 is L and 2
is R (factory setting)
L-D
0 or 3
0 or 3
0 or 3
Start motor strength value of gate
(default)
L-E
30
30
30
Remote learning function: 000 is the
learning state; 253 is the automatic
deletion of the remote control
L-F
0
0
0