www.ZKAccess.com
Page 1: ...www ZKAccess com ...
Page 2: ...wer Wiring Diagram FR1200 Connection Weigand Connection Exit button Connection Lock connection Door Sensor Connection Aux Input Connection Aux Output Connection Ethernet Connection RS485 Connection DIP switch settings Electrical Specifications Troubleshooting Specifications 1 02 04 06 06 07 08 09 10 11 12 12 13 13 15 15 16 17 18 19 20 21 ...
Page 3: ...r or speaker may damage the device Do not place the device next to heating equipments Be careful not to let liquid like water drinks or chemicals leak inside the device Clean the device often to remove dust on it 01 02 03 04 05 06 Do not let children touch the device without supervision The list below is to keep user s safety and prevent any loss Please read carefully before installation ...
Page 4: ...on Do not drop the device Do not use the device for any other purpose than specified Do not disassemble repair or alter the device 07 08 In cleaning do not splash water on the device but wipe it out with smooth cloth or towel 09 Contact your nearest dealer in case of a trouble or problem Do not damage the device 10 11 12 ...
Page 5: ...4 Product Contents Basic Contents Inbio460 Wall Mounting Screws 2 pcs Wall Plugs 2 pcs Surge Suppressing Diode 4 pcs Screw Driver 2 pcs Software CD InBio Installation Guide ...
Page 6: ...5 Product Contents Optional accessories Weigand Card Reader Prox Card Card Enroller ZK4500 FP Enrollment reader FR1200 FP Reader K1 1 Exit Button Inbio Metal Case RS485 convertor ...
Page 7: ...nsor Lock Power Inbio Power LED indicators LINK Green LED solid green indicates TCP IP communication is normal ACT Yellow Flashing LED indicates data communication is in progress EXT RS485 Yellow Green Flashing LED indicates data communication in progress PC RS485 Yellow Green Flashing LED indicates data communication is in progress POWER Red Flashing LED indicates the panel is powered on RUN Gree...
Page 8: ...on Dimensions L W H 400 90 5 330 mm InBio Casing 226mm 8 89in 106mm 4 17in 106mm 4 17in 36mm 1 42in Dimensions L W H 226 106 36 mm 8 89 4 17 1 42 inches 400mm 15 7in 330mm 13 0in 330mm 13 0in 90 5mm 3 56in 15 7 13 0 3 56 inches ...
Page 9: ...8 Installation of Panel Case Metal Case ...
Page 10: ... 9 Detector Infrared sensors FR1200 Inbio Box 1Exit Button 1Card Reader 4 Exit Switch 4 Card Reader 12V Power Supply Normally Open Lock Normally Close Lock Alarm Floodlight RS485 Convertor Network 12V DC Power DC ...
Page 11: ...Power wiring diagram 10 With Backup Battery AC AC Switching power supply Inbio460 AC AC Switching power supply Inbio460 Backup Battery 110 220V 110 220V Without Backup Battery ...
Page 12: ...eader for eg For two readers for one door the RS485 address 1 is for IN reader RS485 address 2 is for OUT reader 3 If FR1200 is powered from Inbio460 panel the length of wire should be less than 100 meters or 330 ft 4 The External RS485 interface can supply maximum 500mA current The FR1200 s startup current is 240mA So Inbio460 only can only power two FR1200s 5 If the cable length is more than 200...
Page 13: ...ion 12 Weigand Card Reader Exit Button Connection Beeper Green LED Weigand D1 Weigand D0 GND DC 6 14V BUT GND DV12V DV12V NO COM NC separate power supply Notice ZK ABK Exit Button K1 1 Exit Switch 12V DC Power Supply ...
Page 14: ...k Connection 12V DC GND Sensor Sensor 12V DC GND GND 12V DC Sensor Sensor GND 12V DC FR107 FR107 For Normally Open Lock powered from panel power supply For Normally Closed Lock powered from panel power supply ...
Page 15: ...cover of inbio460 2 Select the desired lock relay and find its jumpers 3 Take off the jumpers and change to 4 Connect the lock as shown in the diagram below Steps Inbio460 Detach from Rail Remove Top Cover Lock Relay Terminals Default Setting Changed Setting Jumpers FR107 GND 12V DC SEN SEN GND 12V DC 5 1 1 5 5 1 1 5 Connecting a Lock with External Power supply Switching Wet Contact to Dry Contact...
Page 16: ...15 Auxiliary Input Output Aux Input Connection Aux output Connection COM NO NC GND 12V DC COM NO NC GND 12V DC Smoke Detector Alarm ...
Page 17: ...necessary to use a crossover type cable Important Notes ZK4500 Enrollment reader CR10 Card Issuer 1 Both 10Base T and 100Base T are supported 2 The cable length must be less than 100 meters or 330 ft 3 For more than 100 meters please use HUB to amplify the signal TCP IP CR10 Card Issuer ZK4500 Enrollment reader The CR10 and ZK4500 are connected to the server using USB connection ...
Page 18: ...ect by reducing signal reflection during communications 2 A single 485 bus can be connected with 63 access control panels at the most but preferably less than 32 panels should be connected 3 To eliminate signal attenuation in communication cables and suppress interference if the bus is longer than 200 meters set the number 8 DIP switch to the ON position This is equivalent to a parallel connection...
Page 19: ...dress or the device does not work normally you can use the number 7 terminal to restore inbio460 to factory default settings The parameters which gets reset are device IP address communication password gateway subnet mask 2 The switch is OFF by default When it is moved upwards and downwards for three times within 10 seconds and finally returned to OFF position the factory settings will be restored...
Page 20: ...V Use regulated DC power adaptor only Switching Current A 2 Auxiliary relay output Switching voltage V 36V Use regulated DC power adaptor only Switching Current A 1 25 Switch Aux input VIH V TBD VIL V TBD Pull up resistance Ω 4 7k The input ports are pulled up with 4 7k resistors WEIGAND Input Voltage V 10 8 12 13 5 Current mA 500 ZK Electronic lock Voltage V 10 8 12 13 2 Current mA 500 ...
Page 21: ...print is matched but authorization keeps failing Check whether the user access is restricted Inquire with administrator whether the enrolled fingerprint has been deleted from the device for some reason 3 How Many kinds of WEIGAND format can be supported The panel is set to read 26 bit by default However there are 9 other bit formats which can be selected from the software In addition you can also ...
Page 22: ...or two way Number of card readers supported 4 Number of FR1200 supported 8 FR1200 Sensor Fingerprint sensor 500dpi Optical Optical sensor Types of readers supported 26 bit Weigand others upon request Number of Inputs 12 4 Exit Device 4 Door Status 4 AUX Number of Outputs 8 4 Form C relay for lock and 4 Form C relay for Aux output Weight 7 8lbs 3 55kg Enclosure Stainless Steel Mounting Wall Mount D...
Page 23: ...ON OFF 28 OFF OFF ON ON ON OFF 29 ON OFF ON ON ON OFF 30 OFF ON ON ON ON OFF 31 ON ON ON ON ON OFF 32 OFF OFF OFF OFF OFF ON Place Address Switch Setting 1 2 3 4 5 6 Address No 1 2 4 8 16 32 33 ON OFF OFF OFF OFF ON 34 OFF ON OFF OFF OFF ON 35 ON ON OFF OFF OFF ON 36 OFF OFF ON OFF OFF ON 37 ON OFF ON OFF OFF ON 38 OFF ON ON OFF OFF ON 39 ON ON ON OFF OFF ON 40 OFF OFF OFF ON OFF ON 41 ON OFF OFF ...
Page 24: ... Inc All right reserved ZKAccess May at any time and without notice Make changes or improvements to the product and services offered and or cease producing or commercializing them Functions and specifications of the product are subject to change without notice due to quality enhancement or function update For any inquiry for the product please contact ZKAccess Inc ...