background image

CENTER

EDGE

StudScan

DeepScan

SCANNING DIFFERENT SURFACES
Freshly painted walls:

 May take one week or longer 

to dry after application.

Wallpaper:

 The StudSensor

 

HD

70 functions normally 

on walls covered with wallpaper or fabric, unless the 

materials are metallic foil, contain metallic fibers, or are 

still wet after application. 

Wallpaper may need to dry for 

several weeks after application.
Extremely textured walls or acoustic ceilings:

  

When scanning a ceiling or wall with an uneven surface, 

place thin cardboard on the surface to be scanned and 

scan over the cardboard. Calibrate, with cardboard in 

place, in DeepScan

 mode.

Wood flooring, subflooring, or 

gypsum drywall over plywood 

sheathing: 

Use the DeepScan

 

mode and move the tool slowly. 

The Signal Strength Indicator may 

only display 1 or 2 bars when the 

tool locates a stud through thick 

surfaces.

Lath & plaster:

 Due to 

irregularities in plaster thickness, 

this tool is not recommended for 

use on lath & plaster.
StudSensor

 

HD

70 cannot scan  

for studs and joists through 

concrete, carpeting, or padding.  

In StudScan mode, the StudSensor

 

HD

70 will NOT be 

able to scan through dense materials such as glass, 

ceramic tile, and foil. 

Note: Sensing depth and accuracy can vary due to 

moisture, content of materials, wall texture, and paint. 

Indoor use only.

Electrical field locators 

may not detect live AC 

wires if wires are more than 51 mm from the 

scanned surface, in concrete, encased in conduit, 

present behind a plywood shear wall or metallic 

wall covering, or if moisture is present in the 

environment or scanned surface.

DO NOT ASSUME THERE 

ARE NO LIVE ELECTRICAL 

WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT 

COULD BE DANGEROUS IF THE WALL CONTAINS 

A LIVE ELECTRICAL WIRE. ALWAYS TURN OFF THE 

ELECTRICAL POWER, GAS, AND WATER SUPPLIES 

BEFORE PENETRATING A SURFACE. FAILURE TO 

FOLLOW THESE INSTRUCTIONS MAY RESULT IN 

ELECTRIC SHOCK, FIRE, AND/OR SERIOUS INJURY 

OR PROPERTY DAMAGE.
Always turn off power when working near  

electrical wires.

Do not rely exclusively on 

the detector to locate items 

behind the scanned surface. Use other information 

sources to help locate items before penetrating 

the surface. Such additional sources include 

construction plans, visible points of entry of pipes 

and wiring into walls, such as in a basement, and 

in standard 41 and 61 cm stud spacing practices.

3. TURNING ON/CALIBRATING THE TOOL

Place StudSensor

 

HD

70 flat against the wall, then press 

and hold the Power button. The LCD will illuminate 

and display all icons until calibration is complete. Upon 

completion of calibration, the SpotLite

 Pointer and 

buzzer will momentarily activate and the tool will begin 

continuous measurements.

Note: It is important to wait for calibration to 

complete (1–2 seconds) before moving the scanner. 
ACT

 (Auto Correcting Technology):

 During 

scanning, the tool will provisionally recalibrate itself 

when needed. This recalibration is usually transparent 

and no indication is made. If an arrow icon illuminates, 

the tool was calibrated near or over a stud and then 

moved away. The arrow indicates the direction of the 

missed stud.

The Zircon StudSensor

 

HD

70 OneStep

 detects both 

the centre and edges of wood and metal studs and 

joists in walls, floors, and ceilings in one step. It features 

a blue backlit display, Target Spotlight, and patented 

SpotLite

 Pointer.  WireWarning

 detection also 

automatically detects and alerts you of live AC wires. 

1. INSTALLING THE BATTERY

Push in the battery door tab  

at the bottom of the tool and  

open the door. Insert a new 9V  

battery, matching the positive (+)  

and negative (-) terminals to the icons  

printed on the back. Snap the battery 

into place and replace the door.

Low Battery Indicator:

 The Low Battery Indicator  

icon displays when the battery level is getting low.  

While the tool will still operate, the battery will need  

to be replaced soon. When the battery icon begins to 

flash and is the only icon displayed on the screen,  

the battery level is too low and not sufficient to power 

the tool for proper operation. Replace with a brand new 

9V battery immediately. 

2. OPERATING TIPS

For optimum scanning results, it is important to properly 

hold the StudSensor

 

HD

70 and move slowly when 

scanning. The following tips will provide more accurate 

scanning results:
• Grasp the handle with your thumb on one side 

and your fingers on the other side. Make sure your 

fingertips are resting on the tool and not touching  

the surface being scanned or the scanning head of  

the tool.

• Hold the tool straight up and down, parallel to the 

studs, and do not rotate the tool.

SpotLite

 Pointer

Signal  

Strength 

Indicator

Backlit LCD  

Display

Battery  Door Tab

Centre/Edge 

Indication

Low Battery 

Indicator

Target Spotlight

"V" Marker Groove

Auto  

Correcting 

Indication

Target 

Indication 

Bars

WireWarning

™ 

Detection  

Indicator      

StudScan/ 

DeepScan

  

Mode  

Indicators

Power  

Button

LIMITED 1 YEAR WARRANTY

Zircon Corporation, (“Zircon”) warrants this product to be free from defects in materials and workmanship for one year from 

the date of purchase. Any in-warranty defective product returned to Zircon*, freight prepaid with proof of purchase date and 

$5.00 to cover postage and handling, will be repaired or replaced at Zircon’s option. This warranty is limited to the electronic 

circuitry and original case of the product and specifically excludes damage caused by abuse, unreasonable use or neglect. 

This warranty is in lieu of all other warranties, express or implied, and no other representations or claims of any nature shall 

bind or obligate Zircon. Any implied warranties applicable to this product are limited to the one year period following its 

purchase. IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING 

FROM POSSESSION, USE OR MALFUNCTION OF THIS PRODUCT.
In accordance with government regulations, you are advised that: (i) some states do not allow limitations on how long an 

implied warranty lasts and/or the exclusion or limitation of incidental or consequential damages, so the above limitations 

and/or exclusions may not apply to you, and further (ii) this warranty gives you specific legal rights and you may also have 

other rights which vary from state to state.

Return product freight prepaid with proof of purchase date (dated sales receipt) and $5.00 to cover postage and handling, to:
Zircon Corporation 

*Attn: Returns Department 

1580 Dell Avenue 

Campbell, CA 95008-6992 USA
Be sure to include your name and return address. Out of warranty service and repair, where proof of purchase is not 

provided, shall be returned with repairs charged C.O.D. Allow 4 to 6 weeks for delivery.
Customer Service, 1-800-245-9265 or 1-408-963-4550 

Monday–Friday, 8:00 a.m. to 5:00 p.m. PST 

www.zircon.com 

[email protected]
© 2015 Zircon Corporation • P/N 66284 • Rev A 02/15

• Keep the tool flat against the wall and do not rock 

or tilt the tool when slowly sliding across the surface 

being scanned.

• Avoid placing your other hand, or any other part of 

your body, on the surface being scanned. This will 

interfere with the tool’s performance.

• If you're receiving erratic scanning results, it may be  

a result of humidity, moisture within the wall cavity  

or drywall, or recently applied paint or wallpaper that 

hasn't fully dried. While the moisture may not always  

be visible, it will interfere with the tool's sensors. 

Please allow a few days for the wall to dry out.

• Depending on the proximity of electrical wiring or 

pipes to the wall surface, the scanner may detect them 

in the same manner as studs. Caution should always 

be used when nailing, cutting, or drilling in walls, 

floors, and ceilings that may contain these items.

• To avoid surprises, remember that studs or joists are 

normally spaced 41 or 61 cm apart and are 38 mm 

in width. 

Anything closer together or a different 

width may not be a stud, joist, or firebreak.

Always turn off power when working near  

electrical wires.

CEN

TER

EDG

E

StudScan

DeepSca

n

CENTER

EDGE

StudScan

DeepScan

ACT, DeepScan, OneStep, SpotLite, StudSensor, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.

All LCD segments turn on at 

the same time and the tool 

beeps continuously.

Detects other objects 

besides studs. 

You suspect electrical 

wires, but do not 

detect any. 

Area of voltage 

detection is too large.
Flashing Low Battery Indicator 

and tool not operating.

• Unit not flat against wall.
• Unit tilted or lifted during scan. (All these factors affect  

proper calibration.)

• Scanning surface is too dense or too wet for unit to operate.

• Electrical wiring and metal or plastic pipes may be near  

or touching back surface of wall.

• Wires are shielded by metal conduit, a braided wire layer, behind  

metallic wall coverings, plywood shear wall, or other dense material.

• Wires may not be live.
• Wires deeper than 51 mm from surface might not be detected.

• Voltage detection can spread on drywall as much as 30 cm from each 

side of an actual electrical wire.

• Battery level too low for proper operation.

• When scanning an uneven surface, place thin cardboard on the surface to be scanned and scan over  

the cardboard in DeepScan

 mode.

• Grasp the handle with your thumb on one side and your fingers on the other side, not touching the  

surface being scanned or the scanning head of the tool.

• Hold the tool straight up and down, parallel to the studs, and do not rotate the tool.
• If you are using unit on a recently taped, painted, or wallpapered wall, allow time to dry and try again.
• While unit is still on, quickly release and re-press the Power button to enter DeepScan

 mode. 

• Check for other studs equally spaced to either side 30, 41, or 61 cm apart or check for the same stud at 

several places directly above or below the first finding. Studs will run straight up and down from floor to 

ceiling while pipes may change direction.

• A stud reading would measure approximately 38 mm apart from each edge; anything larger or smaller is 

most likely not a stud if not near a door or window.

• Use extra caution if the area has plywood, thick wood backing behind drywall, or thicker than normal walls. 
• If a switch controls an outlet, make sure it is ON for detection, but turned off when working near  

electrical wires.

Use CAUTION when nailing, sawing, or drilling into walls, floors, and ceilings where these items  

may exist.

• To narrow detection, turn unit off and on again at the edge of where wire was detected and scan again.

• Replace with brand new 9V alkaline battery.

8. HELPFUL HINTS

 

(See also Section 2, Operating Tips)

 

Situation

Probable Cause

StudScan

Solution

StudScan

7. WIREWARNING

 DETECTION

Zircon’s WireWarning

 detection works continuously. 

When live AC voltage is detected, the AC WireWarning

 

indicator will appear in the display. If scanning begins 

over a live AC wire, the AC WireWarning

 indicator 

will flash continuously. Use extreme caution in these 

circumstances or whenever live AC is present.

WARNING

4. FINDING A STUD

Always start with the scanner placed flat against the 

wall, then press the Power button. Wait for beep to 

confirm calibration has completed before moving the tool.

Slowly slide tool across 

surface. EDGE indication will 

illuminate, indicating location 

of the stud edge.

Continue sliding tool.  

When the centre of stud is  

located with three bars 

on the Signal Strength 

Indicator, some segments of 

the Target Indication bars, 

CENTER indication, and 

SpotLite

 Pointer will all 

illuminate, and the buzzer 

will sound.

In cases of deeper studs 

(thicker walls), when the 

centre of the stud is located 

only one or two bars will 

show on the Signal Strength 

Indicator and only some 

segments of the Target 

Indication bars will illuminate. 

If you still can’t locate a stud, 

try the next step.

Note: The tool may detect other objects behind the wall 

such as pipes and conduit. See Section 2: Operating Tips 

for ways to confirm that you found a stud.

5. DIFFICULTY LOCATING A STUD?

  TRY DEEPSCAN

 MODE

If you have difficulty locating a stud after following  

Section 4, it could be that the stud is deep (the walls  

are thick). With the unit still placed flat against the  

wall and turned on, quickly (within one second) release 

and re-press the Power button. The StudScan mode 

indication will turn off and the DeepScan

 mode 

indication will turn on, 

indicating that the tool  

has entered DeepScan

 

mode. The centre of a  

very deep stud will be 

indicated by some  

segments of the Target 

Indication bars illuminating.

6. MARKING THE CENTRE OF THE STUD

Once an object is located, mark the location where  

the SpotLite

 Pointer illuminates. This is the centre of  

the stud.

 

EN

StudSensor

 

HD

70

 

OneStep

Centre-Finding Stud Finder

WARNING

WARNING

Visit www.zircon.com/support for the most current instructions.

ZirconCorporation

ZirconTV

ZirconTools

 

|

 

ZirconToolPro

ZirconTools

Summary of Contents for StudSensor HD70 OneStep

Page 1: ... Display Battery Door Tab Centre Edge Indication Low Battery Indicator Target Spotlight V Marker Groove Auto Correcting Indication Target Indication Bars WireWarning Detection Indicator StudScan DeepScan Mode Indicators Power Button EN StudSensor HD70 OneStep Centre Finding Stud Finder ...

Page 2: ...ays when the battery level is getting low While the tool will still operate the battery will need to be replaced soon When the battery icon begins to flash and is the only icon displayed on the screen the battery level is too low and not sufficient to power the tool for proper operation Replace with a brand new 9V battery immediately 2 OPERATING TIPS For optimum scanning results it is important to...

Page 3: ...always be visible it will interfere with the tool s sensors Please allow a few days for the wall to dry out Depending on the proximity of electrical wiring or pipes to the wall surface the scanner may detect them in the same manner as studs Caution should always be used when nailing cutting or drilling in walls floors and ceilings that may contain these items To avoid surprises remember that studs...

Page 4: ...e cardboard Calibrate with cardboard in place in DeepScan mode Wood flooring subflooring or gypsum drywall over plywood sheathing Use the DeepScan mode and move the tool slowly The Signal Strength Indicator may only display 1 or 2 bars when the tool locates a stud through thick surfaces Lath plaster Due to irregularities in plaster thickness this tool is not recommended for use on lath plaster Stu...

Page 5: ...Power button The LCD will illuminate and display all icons until calibration is complete Upon completion of calibration the SpotLite Pointer and buzzer will momentarily activate and the tool will begin continuous measurements Note It is important to wait for calibration to complete 1 2 seconds before moving the scanner ACT Auto Correcting Technology During scanning the tool will provisionally reca...

Page 6: ...e sliding tool When the centre of stud is located with three bars on the Signal Strength Indicator some segments of the Target Indication bars CENTER indication and SpotLite Pointer will all illuminate and the buzzer will sound In cases of deeper studs thicker walls when the centre of the stud is located only one or two bars will show on the Signal Strength Indicator and only some segments of the ...

Page 7: ...ith the unit still placed flat against the wall and turned on quickly within one second release and re press the Power button The StudScan mode indication will turn off and the DeepScan mode indication will turn on indicating that the tool has entered DeepScan mode The centre of a very deep stud will be indicated by some segments of the Target Indication bars illuminating 6 MARKING THE CENTRE OF T...

Page 8: ... works continuously When live AC voltage is detected the AC WireWarning indicator will appear in the display If scanning begins over a live AC wire the AC WireWarning indicator will flash continuously Use extreme caution in these circumstances or whenever live AC is present ...

Page 9: ...ent or scanned surface DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL WIRES IN THE WALL DO NOT TAKE ACTIONS THAT COULD BE DANGEROUS IF THE WALL CONTAINS A LIVE ELECTRICAL WIRE ALWAYS TURN OFF THE ELECTRICAL POWER GAS AND WATER SUPPLIES BEFORE PENETRATING A SURFACE FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK FIRE AND OR SERIOUS INJURY OR PROPERTY DAMAGE Always turn off power when ...

Page 10: ...ut do not detect any Area of voltage detection is too large Flashing Low Battery Indicator and tool not operating Unit not flat against wall Unit tilted or lifted during scan All these factors affect proper calibration Scanning surface is too dense or too wet for unit to operate Electrical wiring and metal or plastic pipes may be near or touching back surface of wall Wires are shielded by metal co...

Reviews: