When the full arrow
is first displayed,
the SpotLite
®
pointer
shines, and a steady
tone sounds, you have
located the edge of the
stud. Mark this spot.
Without releasing
Power button, continue
scanning beyond
marked spot until some
segments of the arrow
turn off. Slide unit in
reverse direction to
locate other edge
of stud.
Mark this second
spot. Middle of stud
is centered between
the two marks.
4. WIREWARNING
®
DETECTION
WireWarning
®
detection works continuously in
STUD SCAN and DEEPSCAN
®
modes. When live
AC voltage is detected, the WireWarning
®
indicator
will appear on the display. If scanning begins over
a live AC wire, the WireWarning
®
indicator will
flash continuously. Use extreme caution in these
circumstances or whenever live AC is present.
Electrical field locators may not
detect live AC wires if moisture
is present in the wall, or if wires are more than
2 in. (51 mm) from the scanned surface, in plastic
conduit or behind a plywood shear wall or
metallic wall covering. Do not rely exclusively on
the detector to locate items behind the scanned
surface. Use other information sources to help
1. INSTALLING THE BATTERY
Push in the battery
door tab at the bottom
of the tool and open
the door.
Insert a new 9-volt
battery, matching the
positive (+) and negative
(-) terminals to the icons
printed on the back. Snap
the battery into place and
replace the door.
2. SELECTING THE MODE
Move selector switch to the desired mode:
STUD SCAN for finding wood or metal studs or
DEEPSCAN
®
for finding studs behind walls more
than
3
⁄
4
in. (19 mm) thick.
Unit will remain off if Power button is not depressed.
3. FINDING A STUD
Always scan for studs with the scanner placed
flat against the wall. Move the mode switch to
STUD SCAN, place the tool flat against the wall,
then press and hold the Power button. Wait for
beep to confirm calibration has completed before
moving scanner.
Continue to hold
the Power button,
then slowly slide unit
horizontally across
the wall, left or right.
As you begin to
approach a stud,
the arrow segments
will begin to turn on.
locate items before penetrating the surface.
Such additional sources include construction
plans, visible points of entry of pipes and
wiring into walls, such as in a basement, and in
standard 16 in. (41 cm) and 24 in. (61 cm) stud
spacing practices.
DO NOT ASSUME THERE
ARE NO LIVE ELECTRICAL
WIRES IN THE WALL. DO NOT TAKE ACTIONS
THAT COULD BE DANGEROUS IF THE WALL
CONTAINS A LIVE ELECTRICAL WIRE. ALWAYS
TURN OFF THE ELECTRICAL POWER, GAS,
AND WATER SUPPLIES BEFORE PENETRATING
A SURFACE. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN ELECTRIC
SHOCK, FIRE, AND/OR SERIOUS INJURY OR
PROPERTY DAMAGE.
5. OPERATING TIPS
For optimum scanning results:
s (OLD THE TOOL STRAIGHT UP AND DOWN PARALLEL TO
the studs, and do not rotate the tool.
s +EEP TOOL FLAT AGAINST THE WALL AND DO NOT ROCK
tilt, or press hard when slowly sliding across the
surface being scanned.
s !VOID PLACING YOUR OTHER HAND OR ANY OTHER
part of your body, on the surface being scanned.
s $EPENDING ON THE PROXIMITY OF ELECTRICAL WIRING
or pipes to the wall surface, the scanner may
detect them in the same manner as studs.
Caution should always be used when nailing,
cutting, or drilling in walls, floors, and ceilings
that may contain these items.
You suspect electrical
wires, but do not
detect any.
Area of voltage
detection appears much
larger than actual wire
(AC only).
s 7IRES MAY BE SHIELDED BEHIND
metallic wall coverings, plywood
shearwall, or other dense material,
or in conduit.
s 4HE WIRES MAY NOT BE LIVE
s 7IRES DEEPER THAN IN MM
from surface may not be detected.
s 6OLTAGE DETECTION CAN SPREAD ON
DRYWALL AS MUCH AS IN CM
from each side of an actual
electrical wire.
All LCD icons
flash and the unit
beeps continuously.
s 3CAN BEGAN ON DENSE PART OF WALL OR
over a stud.
s 5NIT NOT FLAT AGAINST WALL
s 5NIT TILTED OR LIFTED DURING SCAN
(All these factors affect proper
calibration.)
s 3CANNING SURFACE IS TOO DENSE OR TOO
wet for unit to operate.
s 4URN UNIT OFF MOVE OVER A FEW INCHES n CM
press Power button, and start again.
s /N ROUGH SURFACES PLACE A THIN PIECE OF CARDBOARD ON
wall, scanning over it to help slide unit more smoothly.
s +EEP HAND AT LEAST IN CM FROM UNIT WHILE YOU
CALIBRATE AND SCAN (OLD UNIT WITH THUMB AND INDEX
finger no higher than handgrips. Be careful not to
move your fingers after calibration.
s !LWAYS HOLD UNIT PARALLEL TO THE STUD AND MOVE IT
perpendicular to the stud you’re trying to locate.
s )F YOU ARE USING UNIT ON A RECENTLY TAPED PAINTED OR
wallpapered wall, allow time to dry and try again.
Unable to detect studs
in STUD SCAN mode.
Middle LCD segment
doesn’t turn on or flash
in STUD SCAN mode.
s 7ALL IS PARTICULARLY THICK OR DENSE
s 3WITCH TO $%%03#!.
®
mode to locate the stud.
s )NTERPRET THE PAIR OF ,#$ BARS CLOSEST TO THE CENTER AS
stud edge.
The TruCal
®
icon
turns on but, when
scanning, unit doesn’t
do anything else.
s 5NIT MAY NOT BE FLAT AGAINST THE WALL
s )F IT IS IN THE $%%03#!.
®
mode
(DEEPSCAN
®
is lit), you may have
calibrated over a stud.
s (OLD UNIT SO TWO 6ELCRO
®
strips on the back make
contact with wall.
s 2ECALIBRATE UNIT IN A DIFFERENT PLACE AND RESCAN AREA
Working in DEEPSCAN
®
mode and can’t
detect studs.
s 9OU MAY HAVE CALIBRATED OVER A
stud. (The error condition is disabled
in DEEPSCAN
®
mode because it is
twice as sensitive as STUD SCAN.)
s 9OU MAY BE HOLDING THE UNIT LIKE A
46 REMOTE AIMING IT AT THE WALL
s -OVE UNIT OVER A FEW INCHES n CM AND RECALIBRATE
s (OLD UNIT SO TWO 6ELCRO
®
strips on the back make
contact with wall.
Detects other objects
besides studs.
s %LECTRICAL WIRING AND METAL OR PLASTIC
pipes may be near or touching back
surface of wall.
s #HECK FOR OTHER STUDS EQUALLY SPACED TO EITHER SIDE
OR IN OR MM APART OR FOR
the same stud at several places directly above or
below the first scan area.
s 5SE EXTRA CAUTION IF THE AREA HAS PLYWOOD THICK WOOD
backing behind drywall, or thicker-than-normal walls.
s )F A SWITCH CONTROLS AN OUTLET MAKE SURE IT IS /. FOR
detection, but turned off when working near electrical
wires.
Always turn off power when cutting, nailing, or
drilling near electrical wires.
s 4O NARROW DETECTION TURN UNIT OFF AND ON AGAIN AT THE
edge of where wire was detected and scan again.
Always turn off power when cutting, nailing, or
drilling near electrical wires.
Probable Causes
Solutions
Situation
s 4O AVOID SURPRISES REMEMBER THAT STUDS OR
JOISTS ARE NORMALLY SPACED IN CM
OR IN CM APART AND ARE
1
⁄
in.
(38 mm) in width.
Anything closer together
or a different width may not be a stud,
joist, or firebreak.
Always turn off the power when working near
electrical wires.
WORKING WITH DIFFERENT MATERIALS
StudSensor
™
E IS FOR USE ON DRY INTERIOR
walls only.
Note: Sensing depth and accuracy can vary due
to moisture, content of materials, wall texture,
and paint.
StudSensor
™
E CAN SCAN EFFECTIVELY THROUGH
most sheet materials, including:
s "ARE WOOD FLOORING IN $%%03#!.
®
mode)
s ,INOLEUM ON WOOD BASE
s 'YPSUM DRYWALL OVER PLYWOOD SHEATHING
s 7ALLPAPERED WALLS IF DRY
s 4EXTURED CEILINGS IF UNIFORM THICKNESS PLACE A
thin piece of cardboard on ceiling and scan over
it to avoid damage to texturing)
StudSensor
™
E IS NOT DESIGNED TO SCAN
materials such as:
s #ERAMIC FLOOR TILE
s #ARPETING AND PADDING
s 7ALLPAPER WITH METALLIC FIBERS
s &RESHLY PAINTED WALLS THAT ARE STILL DAMP MAY
take one week or longer to dry after application)
s ,ATH AND PLASTER WALLS
s &OIL COVERED INSULATION BOARD
s 'LASS OR ANY OTHER DENSE MATERIAL
StudSensor
™
e
50
Stud Finder
3TUD %DGE 'ROOVE
SpotLite
®
Pointer
WireWarning
®
Detection
Indicator
STUD SCAN
Mode
Power
Button
TruCal
®
Icon
DEEPSCAN
®
Mode
Mode Switch
DeepScan, SpotLite, StudSensor, TruCal, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.
Visit www.zircon.com/support for the most current instructions.
6. HELPFUL HINTS
(See also number 5, Operating Tips)
The StudSensor
™
e
FEATURES TWO
scanning modes:
s 345$ 3#!. ,OCATES THE EDGES
of wood and metal studs up to
3
⁄
4
in. (19 mm) deep
s $%%03#!.
®
: Locates the edges
of wood and metal studs up to
1
1
⁄
in. (38 mm) deep
WireWarning
®
detection automatically
detects and alerts the user to live AC
wires in STUD SCAN and DEEPSCAN
®
modes. When AC voltage is detected,
the AC WireWarning
®
icon will be
displayed on screen.
Note: This product is
intended for use in the
U.S.A. and Canada only.
,)-)4%$ 9%!2 7!22!.49
Zircon Corporation, (“Zircon”) warrants this product to be free from defects
in materials and workmanship for one years from the date of purchase. Any
in-warranty defective product returned to Zircon*, freight prepaid with proof
OF PURCHASE DATE AND TO COVER POSTAGE AND HANDLING WILL BE REPAIRED OR
replaced at Zircon’s option. This warranty is limited to the electronic circuitry and
original case of the product and specifically excludes damage caused by abuse,
unreasonable use or neglect. This warranty is in lieu of all other warranties, express
or implied, and no other representations or claims of any nature shall bind or
obligate Zircon. Any implied warranties applicable to this product are limited to
THE ONE YEAR PERIOD FOLLOWING ITS PURCHASE ). ./ %6%.4 7),, :)2#/. "% ,)!",%
&/2 !.9 30%#)!, ).#)$%.4!, /2 #/.3%15%.4)!, $!-!'%3 2%35,4).' &2/-
0/33%33)/. 53% /2 -!,&5.#4)/. /& 4()3 02/$5#4
In accordance with government regulations, you are advised that: (i) some states
do not allow limitations on how long an implied warranty lasts and/or the exclusion
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS AND
or exclusions may not apply to you, and further (ii) this warranty gives you specific
legal rights and you may also have other rights which vary from state to state.
2ETURN PRODUCT FREIGHT PREPAID WITH PROOF OF PURCHASE DATE DATED
SALES RECEIPT AND TO COVER POSTAGE AND HANDLING TO
Zircon Corporation
!TTN 2ETURNS $EPARTMENT
$ELL !VENUE
#AMPBELL #! 53!
"E SURE TO INCLUDE YOUR NAME AND RETURN ADDRESS /UT OF WARRANTY
service and repair, where proof of purchase is not provided, shall be
RETURNED WITH REPAIRS CHARGED #/$ !LLOW TO WEEKS FOR DELIVERY
#USTOMER 3ERVICE OR
-ONDAYn&RIDAY AM TO PM 0$4
WWWZIRCONCOM s INFO ZIRCONCOM
¥ :IRCON #ORPORATION s 0. s 2EV "
FCC Part 15 Class B Registration Warning
4HIS DEVICE COMPLIES WITH 0ART OF &## 2ULES
/PERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS
(1) this device may not cause harmful interference, and
THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED
including interference that may cause undesired operation.
Battery
Door Tab
WARNING
WARNING