StudSensor
™
e30
Stud Finder
The Zircon StudSensor
™
e30 stud finder finds the edges of
wood and metal studs up to ¾ in. (19 mm) deep in walls. It
features a sleek, high-impact case, with a patented pinch grip
design, and a new SpotLite
®
Pointer.
WireWarning
®
detection automatically detects and alerts the
user of live AC wires. When AC voltage is detected, the AC
WireWarning
®
icon will illuminate.
Note: This product is intended for use in
the U.S.A. and Canada only.
1. INSTALLING THE BATTERY
Do not attempt to unscrew
the back of the tool.
Push in the battery door tab at the bottom
of the tool and open the door.
Insert a new 9 V battery, matching the
positive (+) and negative (-) terminals to
the icons printed on the back. Snap the
battery into place and replace the door.
2. IMPORTANT OPERATING TIPS—
PLEASE READ CAREFULLY
•
Tool Position:
For proper use, always place scanner flat
against the surface before turning on power.
•
Power:
Press and hold the Power button continuously while
in use.
•
Operation:
Move the unit slowly, while keeping it flat
against the wall. Do not rock, tilt, or lift it.
3. FINDING A STUD
Always scan for studs with the scanner placed flat against the
wall. Place the tool flat against the wall, then press and hold
the Power button. Do not move the unit until calibration is
complete. When calibration is complete, the green READY light
will illuminate.
Continue to hold the Power
button, then slowly slide
unit horizontally across the
wall, left or right. As you
begin to approach a stud,
the Arrow segments will
begin to turn on.
Probable Causes
Solutions
Situation
• Move several inches (12–13 cm) to the left or right and start again.
• 9-Volt battery must be installed prior to operation.
• Turn scanner off, move over a few inches (5–6 cm), press
Power button, and start again.
• On rough surfaces, place thin cardboard on wall, scanning
through it to help slide scanner more smoothly.
• Check for other studs equally spaced to either side
(12, 16, or 24 in. [305, 406, or 610 mm] apart) or the same stud
at several places directly above or below the first scan area.
• Use CAUTION when nailing, sawing, or drilling into walls, floors,
and ceilings where these items may exist.
No indications.
Lights start blinking
and unit beeps
repeatedly.
Detects other objects
besides studs.
Finds more targets
than there should be.
• No studs in that area.
• No battery in the unit.
• Tool was calibrated over a
stud or on dense part of wall.
• Tool tilted or lifted during
scan.
• Electrical wiring and metal
or plastic pipes may be
near or touching back
surface of wall.
When the top red EDGE light is
lit, the SpotLite
®
pointer shines,
and a steady tone sounds, you
have located the edge of the
stud. Mark this spot.
Without releasing the Power
button, continue scanning
beyond the marked spot until
the red EDGE light turns off.
Slide unit in reverse direction to
locate other edge of stud.
Mark this second spot. Middle
of stud is centered between the
two marks.
SpotLite
®
Pointer
Stud Edge Groove
Red EDGE Light
Arrow
Segments
Green READY Light
WireWarning
®
Detection Indicator
Battery Door Tab
Power Button
Visit www.zircon.com/support for the most current instructions.
StudSensor, SpotLite, WireWarning, and Zircon are trademarks or registered
trademarks of Zircon Corporation.
The StudSensor
™
e
30 cannot scan for wood studs and joists through ceramic tile or carpeting and pad.
Note: Sensing depth and accuracy can vary due to moisture, content of materials, wall texture, and paint.
LIMITED 1 YEAR WARRANTY
Zircon Corporation, (“Zircon”) warrants this product to be free from defects in materials and
workmanship for one year from the date of purchase. Any in-warranty defective product returned
to Zircon*, freight prepaid with proof of purchase date and $5.00 to cover postage and handling,
will be repaired or replaced at Zircon’s option. This warranty is limited to the electronic circuitry
and original case of the product and specifically excludes damage caused by abuse, unreasonable
use or neglect. This warranty is in lieu of all other warranties, express or implied, and no other
representations or claims of any nature shall bind or obligate Zircon. Any implied warranties
applicable to this product are limited to the one year period following its purchase. IN NO
EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING FROM POSSESSION, USE OR MALFUNCTION OF THIS PRODUCT.
In accordance with government regulations, you are advised that: (i) some states do not allow
limitations on how long an implied warranty lasts and/or the exclusion or limitation of incidental
or consequential damages, so the above limitations and/or exclusions may not apply to you, and
further. (ii) this warranty gives you specific legal rights and you may also have other rights which
vary from state to state.
Return product freight prepaid with proof of purchase date
(dated sales receipt) and $5.00 to cover postage and handling, to:
Zircon Corporation
*Attn: Returns Department
1580 Dell Avenue
Campbell, CA 95008-6992 USA
Be sure to include your name and return address. Out of
warranty service and repair, where proof of purchase is not
provided, shall be returned with repairs charged C.O.D.
Allow 4 to 6 weeks for delivery.
Customer Service: 1-800-245-9265 or 1-408-963-4550
Monday–Friday, 8:00 a.m. to 5:00 p.m. PST
www.zircon.com
E-mail: [email protected]
©2011 Zircon Corporation • P/N 63582 Rev B 07/11
7. HELPFUL HINTS
(See also number 2, IMPORTANT OPERATING TIPS)
FCC Part 15 Class B Registration Warning
This device complies with Part 15 of FCC Rules. Operations subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
4. WIREWARNING
®
DETECTION
WireWarning
®
detection works continuously. When live AC
voltage is detected, the WireWarning
®
detection indicator will
illuminate. If scanning begins over a live AC wire, the WireWarning
®
detection indicator will flash continuously. Use extreme caution
in these circumstances or whenever live AC is present.
Electrical field locators may not
detect live
AC wires if moisture is present
in the wall, or if wires are
more than 2 in. (51 mm) from
the scanned surface, in plastic
conduit or behind a plywood
shear wall or metallic wall covering. Do not rely
exclusively on the detector to locate items behind
the scanned surface. Use other information sources to
help locate items before penetrating the surface. Such
additional sources include construction plans, visible
points of entry of pipes and wiring into walls, such as in
a basement, and in standard 16 in. (406 mm) and 24 in.
(610 mm) stud spacing practices.
DO NOT ASSUME THERE ARE NO LIVE
ELECTRICAL WIRES IN THE WALL. DO
NOT TAKE ACTIONS THAT COULD BE DANGEROUS IF THE
WALL CONTAINS A LIVE ELECTRICAL WIRE. ALWAYS TURN
OFF THE ELECTRICAL POWER, GAS, AND WATER SUPPLIES
BEFORE PENETRATING A SURFACE. FAILURE TO FOLLOW
THESE INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK,
FIRE, AND/OR SERIOUS INJURY OR PROPERTY DAMAGE.
5. OPERATING CAUTIONS
Depending on the proximity of electrical wiring or pipes to the
wall surface, the StudSensor
™
e30 may detect them in the same
manner as studs. Caution should always be used when nailing,
sawing, or drilling into walls, floors, and ceilings that may
contain these items.
To avoid surprises, remember that studs or joists are normally
spaced 16 in. (406 mm) or 24 in. (610 mm) apart and are
1 ½ in. (38 mm) in width.
Anything closer together or a
different width may not be a stud, joist, or firebreak.
Always turn off the power when working near
electrical wires.
6. SCANNING DIFFERENT SURFACES
Freshly painted walls:
May take one week or longer to dry
after application.
Wallpaper:
The StudSensor
™
e30 functions normally on walls
covered with wallpaper or fabric, unless the materials are
metallic foil, contain metallic fibers, or are still wet after application.
Lath & plaster:
Due to irregularities in plaster thickness, this
tool is not recommended for use on lath & plaster.
WARNING
WARNING