background image

REFINE DEEPSCAN

®

 MODE

While in DeepScan

®

 mode, refer to REFINE NORMAL SCAN MODE 

steps 2 – 4. 

STORING REUSABLE ADHESIVE DISKS

This tool comes with 9 double-sided, reusable adhesive disks. 

With repetitive use or exposure to dust particles, disks may 

lose stickiness. Gently wash with soapy water, rinse, air dry, 

and reuse.
The disks can be stored in the case.
To order more reusable adhesive disks,  

email [email protected].

MAGNET SAFETY WARNINGS

The ExitPoint

®

 XL500 magnets are very strong and are more 

powerful than other kinds of magnets. 

HANDLE WITH 

CARE TO AVOID PERSONAL INJURY OR DAMAGE TO  

THE MAGNETS.

 Fingers and other body parts can be pinched 

between two magnets.

1.  KEEP MAGNETS AWAY FROM CHILDREN. 

The ExitPoint

®

 

XL500 magnets are not toys. Children should not be allowed to 

handle these magnets.

2.  EXITPOINT

®

 XL500 MAGNETS CAN  

AFFECT PACEMAKERS.

 

The strong magnetic fields  

near these magnets may affect pacemakers,  

implanted cardioverter defibrillators, and other  

medical devices.

 Many of these devices employ a  

feature that deactivates them with a magnetic field.  

Therefore, 

EXTREME care

 

must be taken to avoid 

inadvertently deactivating such devices.
3.  EXITPOINT

®

 XL500 MAGNETS ARE BRITTLE. 

Despite being made of metal and covered in rubber and plastic, 

these magnets are not as durable as steel and should be handled 

with care. 

DO NOT REMOVE COVERING.

 These magnets can peel, 

chip, crack, or shatter if allowed to slam together. Eye protection 

should be worn since shattering magnets can launch small pieces 

at great speeds.

4.  MAGNETS CAN AFFECT MAGNETIC MEDIA.              

The strong magnetic fields near these magnets can damage 

magnetic media such as floppy disks, credit cards, magnetic 

 

I.D. cards, cassette tapes, video tapes, or other such devices. 

They can also damage wireless phones, televisions, VCRs, 

computer monitors, and CRT displays. 

DO NOT PLACE 

magnets near electronic appliances.
5.  MAGNETS MAY BECOME DEMAGNETIZED AT HIGH 

TEMPERATURES.

 

DO NOT EXCEED 175°F (80°C).

POWER DOWN

To power down, press and hold Power / Mode Button for 

2 seconds. 

Lights will turn off.

Tool will also automatically power down 3 minutes after 

 

last calibration.

USE NORMAL SCAN MODE

The Receiver powers up in Normal Scan Mode,  

as indicated by the Normal Scan Mode  

Indicator light. Always use the Small Target 

Magnet when scanning in this mode. (

Figure A

)

1. 

Determine where the drill exit hole  

should be. Clean the surface of any dust or oils, 

and make sure the surface is dry. 
Remove the protective plastic from both 

sides of an adhesive disk, then use the 

disk to affix the Small Target Magnet to 

the spot, with the yellow side facing away 

from wall. (

Figure B

)

NOTE: Do not discard the protective 

plastic covers for

 

a disk. The disk  

can be reused if covered again and  

stored after use. 
2. 

Hold the Receiver with thumb on one side and fingers on  

the other. Place the Receiver flat against the opposite surface  

from the Target Magnet, but in an area not likely to be over it.

3. 

Power up the Receiver and let 

it calibrate until all LEDs turn on for 

approximately 1 second. 

4. 

Move the Receiver horizontally  

or vertically. The amber Directional 

Indicator LEDs will point toward  

the target. When the Receiver is near 

the Target Magnet, all of the Directional 

Indicator LEDs will light red. Mark the spot 

with a pencil through the Circular Cutout. (

Figure C

)

NOTE: If the unit indicates a large target area, refine the 

scan to more accurately find the target location.

REFINE NORMAL SCAN MODE

1. 

Repeat steps 1 – 3 under USE NORMAL SCAN MODE. 

2. 

Move the Receiver horizontally. The amber Directional 

Indicator LEDs will point toward the target. When the Receiver is 

near the Target Magnet, all of the Directional Indicator LEDs will 

light red. Mark the spot with a pencil through the Circular Cutout. 

(

Figure C

)

3. 

Continue scanning in the same 

direction until the Directional Indicator 

LEDs until the Directional Indicator LEDs 

revert to amber, then reverse direction. 

Mark the location where all of the 

Directional Indicator LEDs light red. 

The approximate midpoint of the target 

is between the two marks. (

Figure D

)

4. 

Without recalibrating, move the 

Receiver to the midpoint, then scan 

vertically until the top and bottom limits 

are marked. The center of the Target 

Magnet should be the midpoint between 

the top and bottom marks. (

Figure E

)

USE DEEPSCAN

®

 MODE

DeepScan

®

 Mode scans up to 9

"

 (22.9 cm) 

thick.
For DeepScan

®

, always use the Large  

Target Magnet. (

Figure F

)

1. 

Determine where the drill exit hole  

should be. Affix the Large Target Magnet to the 

spot with a reusable adhesive disk, yellow side 

facing away from wall.

2. 

Power up Receiver, then double press Power / Mode Button  

to switch to DeepScan

®

 Mode. The DeepScan

®

 Mode Indicator 

light will illuminate.

3. 

Move the Receiver horizontally or vertically. The amber 

Directional Indicator LEDs will point toward the target. When the 

Receiver is near the Target Magnet, all of the Directional Indicator 

LEDs will light red. Mark the spot with a pencil through the  

Circular Cutout. (

Figure C

)

NOTE: If the unit indicates a large target area, refine the 

scan to more accurately find the target location.

LIMITED LIFETIME WARRANTY
Zircon Corporation (“Zircon”) warrants to the original 

purchaser (or original user by gift) that this product will 

be free from defects in materials and workmanship for 

its useful life (not to exceed twenty years from date 

of purchase). This warranty is limited to the electronic 

circuitry of the product, and specifically excludes 

consumable parts, including batteries, and software, even 

if packaged with the product. Defects caused by abuse, 

modification, handling contrary to these instructions, 

other unreasonable use, or neglect are not covered under 

this warranty. No liability is accepted for normal wear 

and tear and minor defects which do not detract from the 

function of the product.
THIS LIMITED LIFETIME WARRANTY IS IN LIEU OF ALL 

OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING 

THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT 

WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INDIRECT, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING 

FROM POSSESSION, USE, OR MALFUNCTION OF THIS 

PRODUCT. NO OTHER REPRESENTATIONS OR CLAIMS OF A 

SIMILAR NATURE WILL BIND OR OBLIGATE ZIRCON.
Some states do not allow limitations on certain implied 

warranties and/or the limitation on incidental or 

consequential damages, so the above limitations and 

exclusions may not apply to you. This warranty gives you 

specific legal rights, and you may also have other rights 

which vary from state to state. This Limited Lifetime 

Warranty applies only to products purchased within the 

United States of America (USA) and Canada. For warranty 

applicable to products purchased in all other geographical 

areas, see www.zircon.com/warranty.

Any defective product returned to Zircon, freight prepaid, 

along with dated purchase receipt and $10.00 to cover 

shipping and handling, will be repaired or replaced, 

at Zircon’s option. If the returned product is no longer 

available, Zircon may replace the product with a similar 

product of similar function. This is your sole and exclusive 

remedy for breach of this Limited Lifetime Warranty. To 

return product, call the Zircon Customer Service number 

below to request an RMA number and return product with 

shipment tracking to:
Zircon Corporation 

Attn: Returns Department 

1580 Dell Avenue 

Campbell, CA 95008-6992 USA
Include your name, return address, RMA number, and 

package tracking number. Allow 4 to 6 weeks for delivery.
If you do not agree to the terms of this Limited Lifetime 

Warranty, you may not use this product and must promptly 

return it to the retailer, along with a dated purchase 

receipt within 30 days of purchase for a refund of the 

purchase price.
Customer Service: 1-800-245-9265 or 1-408-963-4550 

Monday–Friday, 8:00 

a

.

m

.–5:00 

p

.

m

. PT 

www.zircon.com • [email protected]
©2022 Zircon Corporation • P/N 70661 • Rev B 01/22 
DeepScan, ExitPoint and Zircon are trademarks or 

registered trademarks of Zircon Corporation.

BEFORE YOU BEGIN

THIS TOOL WORKS BY DETECTING A HIGH-POWERED MAGNET ON THE OTHER SIDE OF A WALL. IT DOES NOT DETECT STUDS, PIPES,  

OR ELECTRICAL WIRES. 

USE OTHER TOOLS TO DETECT STUDS, PIPES, OR ELECTRICAL WIRES BEFORE DRILLING.

- Always use a new 9V alkaline battery with an extended expiration date, at least 3 years beyond the current date. Match the direction of 

the battery to the clip connector inside the battery cavity.
- Before drilling, use a Zircon

®

 stud finder to scan for studs and other materials at several different heights on the wall and mark the 

location of every target indicated by the scanner. This is called “mapping the wall.” Pipes and other objects will likely not give consistent 

readings from floor to ceiling like a stud will.
- Readings should always be consistent and repeatable.
- Materials more than 9" (22.9 cm) thick may be too thick to scan through.

ExitPoint

®

 XL500

Through-Hole Drill Guide

Visit www.zircon.com for the 

most current instructions.

FCC Part 15 Class B Registration Warning: This device complies  

with Part 15 of FCC Rules. Operation is subject to the following  

two conditions: (1) this device may not cause harmful interference, 

and (2) this device must accept any interference received,  

including interference that may cause undesired operation.

Battery Door Tab 

(door on bottom)

Ergonomic Grip

TROUBLESHOOTING & CONSTRUCTION TIPS

SITUATION

LIKELY CAUSE

SOLUTION

• Receiver does not power on or 

powers off immediately.
• Receiver keeps recalibrating or 

indicating calibration error.
• Ready Indicator is red.

Battery level too low for

  

proper operation.

Replace with brand new 9V alkaline battery.

Solid red Directional Indicator LEDs 

flicker when Receiver is believed to 

be over Target Magnet.

Receiver needs to be recalibrated. 

Move receiver away from suspected target location, recalibrate, then 

restart search for Target Magnet. 

Target Magnet is oriented with  

yellow side towards wall or target  

is too far away.

Orient Target Magnet with yellow side away from wall.

Directional Indicator LEDs

  

continue to flicker after several 

recalibration attempts.

Receiver is unable to locate Target 

Magnet in this particular location.

Change to DeepScan

®

 Mode (Large Target Magnet) and rescan  

for Target Magnet.

Unable to locate Target Magnet.

Target magnet is oriented with  

yellow side facing wall.

Orient Target Magnet away from wall with yellow side facing out.

Receiver is within approximately  

1" (25 mm) of Target Magnet. 

If Receiver is too close to Target Magnet, magnetic lines wrap around 

magnet. Move Receiver further away from Target Magnet and rescan.

Target Magnet distance exceeds 

scan mode specifications.

Check scan depth, Target Magnet size, and scan mode.

Figure B

Directional 

Indicator LEDs 

& Target Indication

Normal Scan 

Mode Indicator

DeepScan

®

 

Mode Indicator

Power / Mode 

Button

Small Target Magnet  

(for Normal Scan)

Large Target Magnet 

(for DeepScan

®

)

NOT SHOWN:

•  9V battery
•  Reusable adhesive disks (9)
•  Protective case for storage and carrying

The Zircon

®

 ExitPoint

®

 XL500 is designed to detect exit points 

through walls before drilling and coring. It operates in one of  

two modes:

• Normal Scan 

is optimized for interior walls with 

1

2

"

 (1.3 cm) 

drywall on both sides, up to 4

1

2

"

 (11.4 cm) thick

• DeepScan

®

 

is for use with thicker walls, up to 9

"

 (22.9 cm)

NOTE

: Accuracy will be impacted unless instructions are 

carefully followed.

Detection depth can vary due to wall material  

and construction.

INSTALL 9-VOLT BATTERY

Install 9V battery, as shown. 

Always use a new 9V alkaline 

battery with an extended 

expiration date at least 3 years 

beyond the current date.
Be sure not to pull on wires when 

disconnecting an old battery.

POWER UP

To activate Receiver, press the Power / Mode Button. 

Lights will flash as tool automatically calibrates, then a beep  

will sound, and the Ready Indicator LED will light green 

to indicate the device is ready for use. 
A calibration error is indicated by top and bottom Directional 

Indicator LEDs flashing alternately with left and right LEDs.  

Move the Receiver away from the suspected location of the  

Target Magnet and recalibrate.

HANDHELD RECEIVER

Figure A

DISPLAY

INDICATES

Normal Scan Mode Indicator LED is illuminated.

Tool is in Normal Scan Mode. Use Small Target Magnet marked 

.

DeepScan

®

 Mode Indicator LED is illuminated.

Tool is in DeepScan

®

 Mode. Use Large Target Magnet marked  .

Amber Directional Indicator LEDs flash in clockwise circular motion.

Tool is calibrating. Wait for it to finish before scanning.

All LEDs on for approximately 1 second. A short beep sounds. 

Calibration is complete. Receiver is ready to scan.

Red LEDs flash.

• Target Magnet detected, but not yet located.
• Detection of stray magnetic fields in DeepScan

®

 Mode.

Red LEDs on.

Target is located.

Amber top and bottom LEDs flash alternately with left and right LEDs.

Calibration error. Recalibrate again.

Ready / Low Battery 

Indicator LED

Figure F

Circular Cutout

6.  MAGNET POWDER OR DUST IS FLAMMABLE. 

Avoid drilling or machining these magnets. When ground into  

a dust or powder, this material is highly flammable.

DO NOT DRILL OR MACHINE.
7.  THOSE WITH NICKEL ALLERGIES SHOULD AVOID 

PROLONGED CONTACT WITH UNCOVERED MAGNETS.   

If you have a nickel allergy, avoid directly handling these 

uncovered magnets.

8.  STRONG MAGNETIC FIELDS CAN INTERFERE WITH 

COMPASSES AND NAVIGATION.

 IATA (International Air 

Transport Association) and US Federal rules and regulations cover 

shipping magnets by air and ground delivery. Magnetic fields  

can influence compasses, magnetometers used in air transport,  

and internal compasses of smartphone and GPS devices.

9.  THESE MAGNETS CAN CORRODE.

 These magnets  

are not waterproof. If used underwater, outdoors, or in  

a moist environment, they can rust, corrode, and lose  

magnetic strength.

WARNING

 

 

- Do not assume there are no live electrical wires in the wall. Do not take actions that could be dangerous if the wall 

contains a live electrical wire. Always turn off the electrical, gas, and water supplies before penetrating a surface.  

Failure to follow these instructions may result in electric shock, fire, and/or serious injury or property damage.
- This tool does NOT detect hidden objects behind a surface. You must use other information sources to locate,  

and avoid, objects behind a surface before drilling.
- Keep magnets away from children, pacemakers, medical, and other electronic devices.
- Fingers can get severely pinched between two attracting magnets.
- Do not dismantle magnet housings. Magnets can peel, crack, or shatter if allowed to slam together.
- Do not expose magnets to magnetic media and other electronics. The strong magnetic fields can damage these items. 
- Keep magnets away from heat and fire. 

MAGNETS

*  and   = South Pole 

*Yellow side = North Pole

Figure D

Figure E

Figure C

EN

Summary of Contents for ExitPoint XL500

Page 1: ...ore than 9 22 9 cm thick may be too thick to scan through ExitPoint XL500 Through Hole Drill Guide WARNING Do not assume there are no live electrical wires in the wall Do not take actions that could be dangerous if the wall contains a live electrical wire Always turn off the electrical gas and water supplies before penetrating a surface Failure to follow these instructions may result in electric s...

Page 2: ...uctions are carefully followed Detection depth can vary due to wall material and construction INSTALL 9 VOLT BATTERY Install 9V battery as shown Always use a new 9V alkaline battery with an extended expiration date at least 3 years beyond the current date Be sure not to pull on wires when disconnecting an old battery POWER UP To activate Receiver press the Power Mode Button Lights will flash as to...

Page 3: ... Repeat steps 1 3 under USE NORMAL SCAN MODE 2 Move the Receiver horizontally The amber Directional Indicator LEDs will point toward the target When the Receiver is near the Target Magnet all of the Directional Indicator LEDs will light red Mark the spot with a pencil through the Circular Cutout Figure C 3 Continue scanning in the same direction until the Directional Indicator LEDs until the Direc...

Page 4: ...near these magnets may affect pacemakers implanted cardioverter defibrillators and other medical devices Many of these devices employ a feature that deactivates them with a magnetic field Therefore EXTREME care must be taken to avoid inadvertently deactivating such devices 3 EXITPOINT XL500 MAGNETS ARE BRITTLE Despite being made of metal and covered in rubber and plastic these magnets are not as d...

Page 5: ...e uncovered magnets 8 STRONG MAGNETIC FIELDS CAN INTERFERE WITH COMPASSES AND NAVIGATION IATA International Air Transport Association and US Federal rules and regulations cover shipping magnets by air and ground delivery Magnetic fields can influence compasses magnetometers used in air transport and internal compasses of smartphone and GPS devices 9 THESE MAGNETS CAN CORRODE These magnets are not ...

Page 6: ...TIME WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION USE OR MALFUNCTION OF THIS PRODUCT NO OTHER REPRESENTATIONS OR CLAIMS OF A SIMILAR NATURE WILL BIND OR OBLIGATE ZIRCON Som...

Page 7: ...ipment tracking to Zircon Corporation Attn Returns Department 1580 Dell Avenue Campbell CA 95008 6992 USA Include your name return address RMA number and package tracking number Allow 4 to 6 weeks for delivery If you do not agree to the terms of this Limited Lifetime Warranty you may not use this product and must promptly return it to the retailer along with a dated purchase receipt within 30 days...

Page 8: ...ts Receiver is unable to locate Target Magnet in this particular location Change to DeepScan Mode Large Target Magnet and rescan for Target Magnet Unable to locate Target Magnet Target magnet is oriented with yellow side facing wall Orient Target Magnet away from wall with yellow side facing out Receiver is within approximately 1 25 mm of Target Magnet If Receiver is too close to Target Magnet mag...