TROUBLE SHOOTING
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
24
ZI-RTR40V-AKKU
NOTICE
The usage of certain solutions containing ingredients damaging metal
surfaces as well as the use of scrubbing agents will damage the machine
surface!
Clean the machine surface with a wet cloth soaked in a mild solution
Never use running water or a high pressure cleaner to clean the machine.
Clean the outer parts with a damp sponge.
Never clean the electronic parts with water!
Check the bottom of the machine (cutting blade area and wheels) and remove the
deposits and / or residues with a brush
Clean the outside (ventilation slots, ...) of the charging station.
14.4
Storage
Clean thoroughly all components before storage.
Store all components separately in a dry area at not less than -10 ° C.
Charge the battery fully before storing.
Store battery and charger separately from the machine
14.5
Disposal
Do not dispose the machine in residual waste. Contact your local authorities for information
regarding the available disposal options. When you buy at your local dealer for a replacement
unit, the latter is obliged to exchange your old.
15
TROUBLE SHOOTING
WARNING
Danger due to electrical voltage! Manipulating the machine when connected to the
power source can cause serious injury or death. Always disconnect the machine from the
power supply before troubleshooting and secure it against unintentional restarting! Repair
work may only be carried out by qualified personnel!
When you are unable to carry out necessary repairs properly and/or do not have the required skills to
do so, always contact a specialist to help you in solving the problem.
Trouble
Possible cause
Solution
Motor does not start
Battery is not plugged in
plug in battery
Battery is not charged
Recharge battery
Switch defect
Check switch
Unusual, loud noises and
excessive vibrations
Loosen cutting tool
Tighten cutting tool
Debris on the cutting tool
Remove derbies
Cutting tool damaged
Change cutting tool
Poor cutting result
Blunt cutting tool
Sharpen or change cutting tool
Battery cannot charged
anymore
Contact failure
Check contact pins
Battery damaged
Change battery