14.2.3
Operation
of the generator
to over
1800m
above sea level
When is operating at high altitudes is due to the lower oxygen content in the air, the air / fuel
mixture too dense. This leads to loss of power, increased fuel consumption and the rapid
deterioration of the spark plugs and heavy start the engine.
the generator is designed to operate at high altitudes, you should modify the carburetor in a
certified service center. Nevertheless, it is a power drop of 3.5% per 300m altitudes to take
slope into account.
CAUTION: The operation of the generator with a modified carburetor at low altitude leads to
overheating of the engine.
AC Operation
Connect the devices to the AC socket. The most devices
need more power for starting than declared. A device with
a rated power (2000kW) can temporarily load your
generator (eg 230V-supply) to its maximum when switched
on.
Always connect the devices in a falling chronology of their
kW-consumption!
When the generator is overloaded the power supply gets
interrupted. So turn off the generator and study the
problem.
Operation
14.4.1
Start
To start the generator, proceed as follows:
Ensure that the generator is in a perfect condition.
When there are some devices connected with the AC sockets you have
to disconnect them.
Open the fuel tap.
Starting the generator with the remote control or with the start key
Key: Turn the key to the „START“ position.
Remote control
Press the „START/ON“ button
14.4.2
Stop
Turn off connected equipment and disconnect from the socket.
To turn off the generator, move the power switch simply to the OFF position.
Close the fuel tap.