POSTFILTER
REPLACEMENT
/ 17
POSTFILTER REPLACEMENT
To change the postfilter, proceed as follows.
1. Remove the back cover. (fig. 7)
2. Pull the postfilter out to free it from the retaining clips. (fig. 8)
3. Disconnect the tubes from the elbow connectors on both ends of the
postfilter. To do this, (1) remove the safety clip from under the collet sleeves
on the elbow connector. (See Fig. 9 and diagrams on page 18 ) (2) Push the
collet sleeves in towards the elbow connector. (3) While holding the collet
sleeves in, pull the tube out of the elbow.
7.
8.
4. Once unscrewed, remove from purifier.
5. Remove new filter from packaging and insert into purifier by gently pushing
upwards while rotating counterclockwise until seated in place. (fig. 6 above)
6. Replace back cover.
7. Reset filter indicator light. See page 22 for filter notice reset procedure.