Instructions. V1.01
Page 2
October / 2013
Description
If the hot water system is not used for two weeks or more, it is recommended
that a hot tap be turned on for several minutes at a sink, basin or bath, it is not
recommended that either a dishwasher, clothes washer or other appliance be used
before the heater is returned to service.
Capacity
:
Underbasin
Overbasin
10 Litre
VP103/UB
VP103
15 Litre
VP153/UB
VP153
These instructions refer to the following models:
These instructions should guide you through the installation, maintenance and use of the
Zip Varipoint II, however, if you require any further information please call Zip customer
service on 0845 6 005 005.
• The Zip Varipoint II is an unvented water heater designed for connection directly to
incoming mains water supply and can serve one or more outlets using conventional
taps.
• Care should be taken that the unit being chosen can meet the demands of the outlets
being supplied.
• The casing is constructed of impact resistant plastic and heat losses are minimised by
the high efficiency CFC free polyurethane foam insulation.
• The inner vessel is constructed from heavy guage copper tested to 1.6MPa (16 bar),
maximum working pressure 0.6MPa (6 bar).
• A manually resettable safety cut-out automatically cuts off the electrical supply to the
heating element in the event of a malfunction..