background image

 

ES3, ES4 & ES6 Instructions. Issue: No. 2 

Page 11  

February / 2012

Electrical connection

Do not switch on the electric power at this time.

WArnIng! To prevent damage to the appliance, the instantaneous water 
heater must be purged of air before using it for the first time

.

PUrgIng

Before connecting the electrical supply, open and close the hot water tap until 
the water runs smoothly and no more air emerges.

nOTE! Every time the appliance is drained (e.g. after work on the 
plumbing system, if there is a risk of frost or following repair work), 
the heater must be purged in this way before reconnecting the power 
supply.

WARNING! This appliance must be earthed. 
Installation must be carried out by a competent electrician.

The electrical installation including earthing and cross bonding should comply with 
current IEE regulations and any Local Authority requirements.

IMPOrTAnT: 

The appliance must be installed according to the specification on 

the rating plate and the technical specifications. Ensure that the voltage marked 
on the appliance matches the power supply.
The appliance must be permanently connected to the electrical supply through 
an isolation switch having a contact separation of at least 3mm on all poles.  
To protect the appliance, a circuit breaker must be fitted with a rating suitable for 
the nomi nal current of the appliance. 
The cross sectional area of the connection cable must be in accordance with the 
power rating of the appliance and the specific requirements of the installation site.
Take care to protect the wiring from damage during installation and ensure that 
any uninsulated wiring is not directly accessible after installation.
The cable must be adequately secured.

WARNING!

 Check that the power supply is switched off prior to electrical 

connection!

  

               

Fig. 6

3

2

1

Circuit Diagram

1. Electronic regulator

2. Safety thermal cut-out

3. Heating element

PE

N

L

Summary of Contents for InLine ES3

Page 1: ...tructions carefully before commencing installation of the InLine water heater Please leave these instructions with the end user after installation Zip Heaters UK Ltd 14 Bertie Ward Way Dereham Norfolk...

Page 2: ...Inside Back Cover Inside Front Cover...

Page 3: ...ning 13 Fault finding 14 Warranty 16 Please read these instructions carefully before commencing installation of the InLine Electronic Instantaneous Water Heater Please leave these instructions with th...

Page 4: ...ower temperature is required If the flow rate is too low or if the hot water tap is closed the appliance switches itself off automatically For an optimum flow of water always fit the special jet regul...

Page 5: ...nction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carried out by Zip Heaters UK Ltd or an authorised Zip service engineer Temperatures in...

Page 6: ...must be vented by opening and closing the hot water tap until all air has been eliminated from the water heater and no more air emerges before re connecting to the electrical supply The appliance must...

Page 7: ...on flow rate l min 1 2 1 5 1 5 Switch off flow rate l min 1 0 1 3 1 3 Minimum differential pressure factory set flow rate 0 025 MPa 0 25 bar 0 05 MPa 0 50 bar 0 075 MPa 0 75 bar Factory set temperatur...

Page 8: ...ll bracket only 4 IN80353 Set of small spare parts seals nozzle for cable entry etc 5 IN80080 Filter sieve fine filter 6 IN80750 Water connection set including two water connections and seals 7 IN8037...

Page 9: ...ectional area of the connection cable must be in accordance with the power rating of the appliance and the specific requirements of the installation site Take care to protect the wiring from damage du...

Page 10: ...an be checked with the local water supply company Thoroughly flush the water supply pipes before installation to remove any water borne debris Installing the appliance 1 Secure the wall bracket to the...

Page 11: ...ipe connectors Fig 3 2 When supplying mixer taps a non return valve must be fitted to the hot water outlet and not to the cold water inlet fig 5 3 A flow control valve may be required on the cold supp...

Page 12: ...4 5 show unvented installation with closed outlet tap Fig 4a shows open vented installation Fig 4 You may also use an open vented installation 187mm 132mm Fig 5 Service Valve Flow Control Valve Mains...

Page 13: ...rity requirements Important The appliance must be installed according to the specification on the rating plate and the technical specifications Ensure that the voltage marked on the appliance matches...

Page 14: ...eved Water too cold Increase the temperature by turning the potentiometer counter clockwise until the desired temperature is achieved If the desired temperature cannot be achieved the red LED on the P...

Page 15: ...cleaned at regular intervals Rinse the regulator with water and brush off the debris For difficult to remove deposits soak in white vinegar or a proprietary scale cleaner for a few minutes and scrub w...

Page 16: ...lve shut off valve Water flows more slowly than expected The Jet Regulator is not fitted Fit the correct Jet Regulator see Fig 5 Water pressure is not sufficient Check the water flow pressure check th...

Page 17: ...incorrect Check the electric supply Circuit breaker has tripped Safety thermal cut out has tripped Have the fault rectified by a technician and reset the circuit breaker thermal cut out Hot water tem...

Page 18: ...ent of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any ot...