806834 v1.02 07.21 G5 Online install instructions and user guide
30
4.1 Generic installation arrangement instructions
Read these instructions together with those supplied with individual components
before commencing Command Centre installation,they apply to all installation
arrangements.
90º bend
Command Centre
Braided hose for mains
water supply
Mains cold
water supply
!
• Install the mains water braided hoses to the Command Centre
before locating in place. See below.
• Ambient mains water braided hose length is 750mm.
• Electrical power cable is 1.8m long.
• The Command Centre
must be installed within the limits of the
hose and cable lengths supplied.
• All silicon tubes / plastic pipes must be cut to size. They must
have a constant fall back to the Command Centre.
• Isolation valves are not supplied.
Tubes and pipes
• Take care to install correctly. No kinks, sags, pinches or loops.
Tips for connection
• Push the silicone hose over the connector for a minimum of 15mm.
• Ensure there a constant fall from the tap down to the Command Centre.
• Tubes and pipes must be trimmed to avoid loops and kinks. Take care when positioning before cutting
and make a clean cut straight across the hose, using a sharp blade.
• The tubes and pipes must not be under tension when installed.
Section 4 Commercial & Residential Command Centre installation
Inline filter
adaptor
Inline filter