![Zip HydroTap G4 802701 User Manual Download Page 19](http://html1.mh-extra.com/html/zip/hydrotap-g4-802701/hydrotap-g4-802701_user-manual_3887716019.webp)
802701 - G4 User Guide - 09.2016 - v2.02
Page 19 of 24
2.6kg Gas bottle Change
1.
Turn the CO
2
bottle, black knob, OFF (Clockwise).
2.
Turn the regulator, grey knob, all the way out (Anti clockwise).
3.
Dispense sparkling water for 30 seconds, until the water flow is free of gas
4.
Remove the regulator assembly from the bottle by unscrewing the large
chrome nut. It is not necessary to remove the hose from the regulator. Be
aware that some CO
2
may be discharged from the bottle joint.
5.
Be careful not to lose the plastic sealing washer, inside the chrome nut.
6.
If the hose is removed from the regulator, be careful not to lose the sealing
olive
7.
Remove the bottle from the cradle by loosening the hook-and-loopsecuring
strap.
8.
Fit the regulator and hose assembly to the new gas bottle. Ensure all the
seals are in place.
9.
Fit the bottle in an upright position (use the hook-and-loopsecuring strap).
10.
Turn the regulator grey knob, ON (Clockwise) and adjust to betweem 2.7-
3.0 bar. (Green zone on dial).
11.
Check all joints for gas leaks using a sponge and soapy water.
12.
Press the [MENU] button for main menu.
13.
Press the [Install] button.
14.
Press the [Purge CO
2
] button.
15.
In the next screen, press the
[START] button to commence the
purging process.
16.
Wait for the water to stop flowing
through the unit. Wait a further
10 seconds after the water has
stopped flowing. You will hear the
CO
2
gas escaping through the tap.
17.
Press [STOP] to end the purge
18.
Press [<=] button for the previous
menu or press the [Home] button to
return to the home screen.
19.
The display screen should revert to
Normal operation.
20.
Dispense some sparkling water from the tap and perform a taste test.
Note: Do not discard your empty 2.6kg bottle.
The 2.6kg bottles are refillable. Return the empty bottle to your nearest Zip
service centre for exchange.