LCD Screen operation - Section G
Sleep Mode
Light
Level
Time
Delay
State
Boiler
Chiller
2 Hours-> 68°C
N/A
2 Hr
Sleep
68°C
ON
2 Hours-> OFF
N/A
2 Hr
OFF
OFF
OFF
Lux Sensor->68°C
Dark
N/A
Sleep
68°C
ON
Lux Sensor-> OFF
Dark
N/A
OFF
OFF
OFF
Lux or 2 Hr-> 68°C
Dark
2 Hr
Sleep
68°C
ON
Lux or 2 Hr-> OFF
Dark
2 Hr
OFF
OFF
OFF
Disable
N/A
N/A
ON
ON
ON
This mode allows the HydroTap to Go into Energy Saving mode. There are
two options available: ‘Sleep’ mode and ‘ON/OFF’ mode.
To activate the sleep mode:
1.
Press [MENU] button for main
menu.
2.
Press [Setting] button.
3.
Press [Energy Modes] button.
4.
Press [Sleep Modes] button then
in the next screen, use the up and
down arrows to select one of the
7 options, as shown in the table
below.
Energy Modes
(Boiling models)
In SLEEP MODE
the unit will Go to “Sleep” after a 2hr period of
inactivity. The Boiling water will gradually drop to either 68°C or room temp,
as shown in the table below and the Chilled water will be ON or OFF.
When the period of inactivity passes, the home screen status window will
show “Sleep Mode”.
Lux (Light) Sensor Calibration:
It is recommended to recalibrate the Lux (Light) Sensor after selecting any of
the 4 Lux sensor options from the sleep mode menu. Before commencing,
ensure there are ‘Normal to Dim’ (Not Dark) operating light conditions.
Note:
Refer to section C5 on Page 12 for calibration procedure
Note:
Any attempt, during OFF mode, to dispense water, will bring the unit
out of sleep mode. The unit will return to sleep mode after 2 hours of non
use. Please allow sufficient time for the water to reach the set temperature